• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-906 Public Water Supply

NYC 1968 Code (Vol I) > 16 Plumbing and Gas Piping > 2 Water Supply Systems > §27-906 Public Water Supply
JUMP TO FULL CODE CHAPTER
(a) Required capacity. Where the required capacity of potable water supply is available from street water mains at the site, every building shall be supplied from such mains.

(b) Power pumps. When power pumps are required in the water supply system of a building, they shall take their supply from the street water mains in the manner prescribed in reference standard RS-16.

Related Code Sections


§27-906 Plumbing and Gas Piping, Public Water Supply
(a) Required capacity. Where the required capacity of potable water supply is available from street water mains at the site, every building shall ...
NYC 1968 Code (Vol I) > 16 Plumbing and Gas Piping > 2 Water Supply Systems > §27-906 Public Water Supply
601.5 Water Supply and Distribution, Water Supply
dwelling, if a property line of such building is within 500 feet (152 m), measured along a street, alley, or right-of-way, of the public water supply ...
NYC Plumbing Code 2008 > 6 Water Supply and Distribution > 601 General > 601.5 Water Supply
601.5 Water Supply and Distribution, Water Supply
dwelling, if a property line of such building is within 500 feet (152 m), measured along a street, alley, or right-of-way, of the public water supply ...
NYC Plumbing Code 2014 > 6 Water Supply and Distribution > 601 General > 601.5 Water Supply
Section 601 Water Supply and Distribution, General
, of the public water supply system. The extension and connection shall be made in accordance with the applicable standards of the Department ...
NYC Plumbing Code 2014 > 6 Water Supply and Distribution > 601 General
606.1 Water Supply and Distribution, Location of Full-Open Valves
Full-open valves shall be installed in the following locations:   1. On the building water service pipe from the public water supply near ...
NYC Plumbing Code 2008 > 6 Water Supply and Distribution > 606 Installation of the Building Water Distribution System > 606.1 Location of Full-Open Valves
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE