• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

503.3 Public Streets

NYC Fire Code 2014 > 5 Fire Operations Features > 503 Fire Apparatus Access > 503.3 Public Streets
JUMP TO FULL CODE CHAPTER
Buildings fronting on public streets shall comply with the requirements of FC 503.3.1 and 503.3.2.

503.3.1 Dead-End Turnarounds

Dead-end public streets in excess of 150 feet (45 720 mm) in length, as measured from the curb line of the nearest public street that is not a dead-end, shall be provided with an approved turnaround area for fire apparatus that complies with the requirements of FC503.2.9.

Exception: A turnaround shall not be required for dead-end public streets more than 150 feet (45 720 mm) in length if all buildings on such street further than 150 feet (45 720 mm) from the curb line of the nearest street that is not a dead-end are protected throughout by a sprinkler system, excluding buildings in which the lack of a sprinkler system is a lawfully existing condition pursuant to FC 102.3, 102.4 and 102.5.

503.3.2 Substandard Width

Buildings on public streets that have an unobstructed width of less than 34 feet (10 363 mm) shall be protected throughout by a sprinkler system. Buildings on substandard width public streets that were not required prior to the effective date of this section to be protected throughout by a sprinkler system shall comply with this requirement when undergoing alteration or a change of occupancy subject to FC501.4.3. This requirement shall not apply to any Group U occupancy complying with the requirements of FC503.2.10.

Related Code Sections


§27-940 Fire Alarm, Detection and Extinguishing Equipment, Siamese Connections Required
or fraction thereof facing upon each street or public space. (b) Where buildings face upon two parallel streets or public spaces without ...
NYC 1968 Code (Vol I) > 17 Fire Alarm, Detection and Extinguishing Equipment > 3 Standpipe Requirements > §27-940 Siamese Connections Required
912.2.1 Fire Protection Systems, Fire Department Connections
upon each street or public space. Where buildings face ...
NYC Building Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location > 912.2.1 Fire Department Connections
1025.1 Means of Egress, General
street, public alley, yard or court.    Exceptions:   1. Buildings equipped throughout with an approved automatic sprinkler ...
NYC Building Code 2008 > 10 Means of Egress > 1025 Emergency Escape and Rescue > 1025.1 General
Reference Standard 16 Plumbing and Gas Piping [PDF] (page 48)
Reference Standard 16 determines that no public street storm sewer or public street combined sewer is located directly in front of any point of any ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 16 Plumbing and Gas Piping
1104.1 Accessibility, Site Arrival Points
, and public streets or sidewalks to the accessible building entrance served ...
NYC Building Code 2008 > 11 Accessibility > 1104 Accessible Route > 1104.1 Site Arrival Points
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE