• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

93-74 Public Access Areas in Pennsylvania Station Subarea B4

NYC Zoning Resolution > IX Special Purpose Districts > 3 - Special Hudson Yards District (HY) > 93-70 Public Access Requirements for Special Sites > 93-74 Public Access Areas in Pennsylvania Station Subarea B4
JUMP TO FULL CODE CHAPTER

The provisions of this Section shall apply to any development in the Pennsylvania Station Subarea B4 of the Farley Corridor Subdistrict B.

(a)        Public space

A publicly accessible enclosed space with a minimum area of 32,500 square feet shall be provided. Such space shall have at least 100 feet of frontage along the Eighth Avenue street line, and have a minimum clear height of 60 feet. The length of such space shall not exceed four times its narrowest width. Up to one-half of such space may be below- grade but shall be visually connected to the at-grade space. Furthermore, such below-grade space shall be connected to the at-grade space by escalators on at least two sides. The retail and glazing requirements of Section 93-14 (Ground Floor Level Requirements) shall apply to least 70 percent of the length of all building walls facing each side of such space. Such space shall provide direct access to the through block connection required pursuant to paragraph (b) of this Section, adjacent building lobbies and transit facilities.

(b)        Through block connection

A through block connection shall be provided linking West 31st Street and West 33rd Street, at least 300 feet from Eighth Avenue and with direct access to the public space required pursuant to paragraph (a) of this Section. Such through block connection shall have a minimum clear width of 20 feet and may be open or enclosed. If enclosed, such through block connection shall have a minimum clear height of 30 feet.

(c)        Plaza

A publicly-accessible plaza, open to the sky, may be provided at the intersection of Eighth Avenue and West 31st Street. Such plaza shall have a minimum area of 12,000 square feet with a minimum frontage of 60 feet along West 31st Street, and be provided in accordance with the standards for public plazas set forth in Section 37-70, inclusive.

(d)        Corner circulation space

Corner circulation spaces shall be provided at the corners of Eighth Avenue and West 31st Street and Eighth Avenue and West 33rd Street. Such spaces shall comply with the requirements for corner circulation spaces of paragraph (d) of Section 37-53. Such spaces shall count towards meeting the pedestrian circulation space requirements of Section 93-63. However, no corner circulation space shall be required at the corner of Eighth Avenue and West 31st Street if a plaza is provided at such corner in accordance with paragraph (c) of this Section.

Related Code Sections


Section E109 Supplementary Accessibility Requirements, Transportation Facilities and Stations
of one tactile sign identifying the specific station shall be provided on each platform or boarding area. Such signs shall be placed in uniform ...
NYC Building Code 2014 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations
Section E109 Supplementary Accessibility Requirements, Transportation Facilities and Stations
of one tactile sign identifying the specific station shall be provided on each platform or boarding area. Such signs shall be placed in uniform ...
NYC Building Code 2008 > E Supplementary Accessibility Requirements > E109 Transportation Facilities and Stations
1109.7 Accessibility, Lifts
reporters' stations; and to depressed areas such as the well of the court. An accessible route where existing exterior site constraints make use ...
NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.7 Lifts
Section 1103 Accessibility, Scoping Requirements
of seating, tables and/or work stations, if provided, within employee work areas shall comply with applicable sections of ICC A117.1 ...
NYC Building Code 2014 > 11 Accessibility > 1103 Scoping Requirements
1103.2 Accessibility, General Exceptions
agricultural buildings and livestock shelters, access is required to paved work areas and areas open to the general public. Green houses and stables open ...
NYC Building Code 2014 > 11 Accessibility > 1103 Scoping Requirements > 1103.2 General Exceptions
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE