Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path.

EXCEPTION: Handrails shall be permitted to protrude 4 1/2 inches (115 mm) maximum.
Advisory 307.2 Protrusion Limits.  When a cane is used and the element is in the detectable range, it gives a person sufficient time to detect the element with the cane before there is body contact.  Elements located on circulation paths, including operable elements, must comply with requirements for protruding objects.  For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance.  Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm).
Figure 307.2 Limits of Protruding Objects
A frontal view shows a person using a cane walking along a wall.  A wall-mounted object more than 27 inches (685 mm) from the floor protrudes no more than 4 inches (100 mm) from the wall surface.  An object overhead provides vertical clearance that is greater than 80 inches (2030 mm).

Related Code Sections

307.2 Building Blocks, Protrusion Limits
Advisory 307.2 Protrusion Limits.  When a cane is used and the element is in the detectable range, it gives a person sufficient time to detect ...
604.5 Plumbing Elements and Facilities, Grab Bars
, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide ...
408 Accessible Routes, Limited-Use / Limited-Application Elevators
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter ...
203.4 Scoping Requirements, Limited Access Spaces
Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements ...