// CODE SNIPPET
1910.266(f)(3) Protective Structures
JUMP TO FULL CODE CHAPTER
Each tractor, skidder, swing yarder, log stacker, log loader and mechanical felling device, such as tree shears or feller-buncher, placed into initial service after February 9, 1995, shall be equipped with falling object protective structure (FOPS) and/or rollover protective structure (ROPS). The employer shall replace FOPS or ROPS which have been removed from any machine. Exception: This requirement does not apply to machines which are capable of 360 degree rotation.
FOPS shall be installed, tested and maintained in accordance with the Society of Automotive Engineers SAE J231, January 1981, "Minimum Performance Criteria for Falling Object Protective Structures (FOPS)", which is incorporated by reference as specified in Sec. 1910.6.
ROPS and FOPS shall meet the requirements of the Society of Automotive Engineers SAE J397, April 1988, "Deflection Limiting Volume-ROPS/FOPS Laboratory Evaluation", which is incorporated by reference as specified in Sec. 1910.6.
The enclosure of the upper portion of each cab shall allow maximum visibility.
Each protective structure shall be of a size that does not impede the operator's normal movements.
The overhead covering of each cab shall be of solid material and shall extend over the entire canopy.
Each machine manufactured after August 1, 1996, shall have a cab that is fully enclosed with mesh material with openings no greater than 2 inches (5.08 cm) at its least dimension. The cab may be enclosed with other material(s) where the employer demonstrates such material(s) provides equivalent protection and visibility. Exception: Equivalent visibility is not required for the lower portion of the cab where there are control panels or similar obstructions in the cab, or where visibility is not necessary for safe operation of the machine.
Each machine manufactured on or before August 1, 1996 shall have a cab which meets the requirements specified in paragraph (f)(3)(vii) or a protective canopy for the operator which meets the following requirements:
The protective canopy shall be constructed to protect the operator from injury due to falling trees, limbs, saplings or branches which might enter the compartment side areas and from snapping winch lines or other objects;
The lower portion of the cab shall be fully enclosed with solid material, except at entrances, to prevent the operator from being injured from obstacles entering the cab;
The upper rear portion of the cab shall be fully enclosed with open mesh material with openings of such size as to reject the entrance of an object larger than 2 inches in diameter. It shall provide maximum rearward visibility; and
Open mesh shall be extended forward as far as possible from the rear corners of the cab sides so as to give the maximum protection against obstacles, branches, etc., entering the cab area.
When transparent material is used to enclose the upper portion of the cab, it shall be made of safety glass or other material that the employer demonstrates provides equivalent protection and visibility.
Transparent material shall be kept clean to assure operator visibility.
Transparent material that may create a hazard for the operator, such as but not limited to, cracked, broken or scratched safety glass, shall be replaced.
Deflectors shall be installed in front of each cab to deflect whipping saplings and branches. Deflectors shall be located so as not to impede visibility and access to the cab.
The height of each cab entrance shall be at least 52 inches (1.3 meters) from the floor of the cab.
Each machine operated near cable yarding operations shall be equipped with sheds or roofs of sufficient strength to provide protection from breaking lines.
ROPS shall be tested, installed, and maintained in serviceable condition.
Each machine manufactured after August 1, 1996, shall have ROPS tested, installed, and maintained in accordance with the Society of Automotive Engineers SAE J1040, April 1988, "Performance Criteria for Rollover Protective Structures (ROPS) for Construction, Earthmoving, Forestry, and Mining Machines", which is incorporated by reference as specified in Sec. 1910.6.
Related Code Sections
1910.266(f)(3) Special Industries, Protective Structures
into initial service after February 9, 1995, shall be equipped with falling object protective structure (FOPS) and/or rollover protective structure (ROPS). The ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(f) Machines > 1910.266(f)(3) Protective Structures
1910.266(f)(3)(iii) Special Industries,
Criteria for Falling Object Protective Structures (FOPS)", which is incorporated by reference as specified in Sec. 1910.6 ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(f) Machines > 1910.266(f)(3) Protective Structures > 1910.266(f)(3)(iii)
1910.266(f)(3)(iv) Special Industries,
ROPS and FOPS shall meet the requirements of the Society of Automotive Engineers SAE J397, April 1988, "Deflection Limiting Volume-ROPS/FOPS ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(f) Machines > 1910.266(f)(3) Protective Structures > 1910.266(f)(3)(iv)
1910.266(f)(3)(ix) Special Industries,
The enclosure of the upper portion of each cab shall allow maximum visibility ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(f) Machines > 1910.266(f)(3) Protective Structures > 1910.266(f)(3)(ix)
1910.266(f)(3)(v) Special Industries,
Each protective structure shall be of a size that does not impede the operator's normal movements ...
OSHA 1910 General Industry > R Special Industries > 1910.266 Logging Operations > 1910.266(f) Machines > 1910.266(f)(3) Protective Structures > 1910.266(f)(3)(v)