1910.1044(j) Protective Clothing and Equipments
JUMP TO FULL CODE CHAPTER
Where there is any possibility of eye or dermal contact with liquid or solid DBCP, the employer shall provide, at no cost to the employee, and assure that the employee wears impermeable protective clothing and equipment to protect the area of the body which may come in contact with DBCP. Eye and face protection shall meet the requirements of § 1910.133 of this part.
The employer shall assure that employees remove DBCP contaminated work clothing only in change rooms provided in accordance with paragraph (l)(1) of this section.
The employer shall assure that no employee takes DBCP contaminated protective devices and work clothing out of the change room, except those employees authorized to do so for the purpose of laundering, maintenance, of disposal.
DBCP-contaminated protective devices and work clothing shall be placed and stored in closed containers which prevent dispersion of the DBCP outside the container.
Containers of DBCP-contaminated protective devices or work clothing which are to be taken out of change rooms or the workplace for cleaning, maintenance or disposal shall bear labels with the following information: CONTAMINATED WITH 1,2-Dibromo-3-chloropropane (DBCP), MAY CAUSE CANCER.
The employer shall assure that employees promptly remove any protective clothing and equipment which becomes contaminated with DBCP-containing liquids and solids. This clothing shall not be reworn until the DBCP has been removed from the clothing or equipment.
The employer shall clean, launder, repair, or replace protective clothing and equipment required by this paragraph to maintain their effectiveness. The employer shall provide clean protective clothing and equipment at least daily to each affected employee.
The employer shall prohibit the removal of DBCP from protective clothing and equipment by blowing or shaking.
The employer shall inform any person who launders or clean DBCP-contaminated protective clothing or equipment of the potentially harmful effects of exposure to DBCP.
Related Code Sections
1910.1029(h) Toxic and Hazardous Substances, Protective Clothing and Equipment
Provision and use. The employer shall provide and assure the use of appropriate protective clothing and equipment, such as but not limited ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(h) Protective Clothing and Equipment
1910.1044(j) Toxic and Hazardous Substances, Protective Clothing and Equipments
that the employee wears impermeable protective clothing and equipment to protect the area of the body which may come in contact with DBCP. Eye ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1044 1,2-Dibromo-3-Chloropropane > 1910.1044(j) Protective Clothing and Equipments
1910.1045(j) Toxic and Hazardous Substances, Protective Clothing and Equipment
, impermeable protective clothing or other equipment to protect any area of the body which may come in contact with liquid AN. The provision of 1910.132 ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1045 Acrylonitrile > 1910.1045(j) Protective Clothing and Equipment
1910.1047(g)(4) Toxic and Hazardous Substances, Protective Clothing and Equipment
, appropriate protective clothing or other equipment in accordance with 29 CFR 1910.132 and 1910.133 to protect any area of the employee's body that may come ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1047 Ethylene Oxide > 1910.1047(g) Respiratory Protection and Personal Protective Equipment > 1910.1047(g)(4) Protective Clothing and Equipment
1910.1024(h) Toxic and Hazardous Substances, Personal Protective Clothing and Equipment—
The employer must provide at no cost, and ensure that each employee uses, appropriate personal protective clothing and equipment in accordance ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1024 Beryllium > 1910.1024(h) Personal Protective Clothing and Equipment—