• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2404.5.2 Protection of Sprinklers

Fire Code 2018 of Kansas > 24 Flammable Finishes > 2404 Spray Finishing > 2404.5 Housekeeping, Maintenance and Storage of Hazardous Materials > 2404.5.2 Protection of Sprinklers
JUMP TO FULL CODE CHAPTER
Automatic sprinklers installed in flammable vapor areas shall be protected from the accumulation of residue from spraying operations in an approved manner. Bags used as a protective covering shall be 0.003-inch-thick (0.076 mm) polyethylene or cellophane or shall be thin paper. Automatic sprinklers contaminated by overspray particles shall be replaced with new automatic sprinklers.

Related Code Sections


2404.5.2 Flammable Finishes, Protection of Sprinklers
Automatic sprinklers installed in flammable vapor areas shall be protected from the accumulation of residue from spraying operations ...
Fire Code 2018 of Kansas > 24 Flammable Finishes > 2404 Spray Finishing > 2404.5 Housekeeping, Maintenance and Storage of Hazardous Materials > 2404.5.2 Protection of Sprinklers
23.6* Plans and Calculations, Exposure Protection Sprinkler Systems
Exposure protection sprinkler systems shall be hydraulically calculated using Table 23.6.1 based on severity of exposure as indicated by a relative ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 23 Plans and Calculations > 23.6* Exposure Protection Sprinkler Systems
8.5.2 Installation Requirements, Protection Areas Per Sprinkler
The protection area of coverage per sprinkler ( A S ) shall be determined as follows: Along branch lines as follows: Determine distance ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 8 Installation Requirements > 8.5 Position, Location, Spacing, and Use of Sprinklers > 8.5.2 Protection Areas Per Sprinkler
3504.1.8 Welding and Other Hot Work, Sprinkler Protection
Automatic sprinkler protection shall not be shut off while hot work is performed. Where hot work is performed close to automatic sprinklers ...
Fire Code 2018 of Kansas > 35 Welding and Other Hot Work > 3504 Fire Safety Requirements > 3504.1 Protection of Combustibles > 3504.1.8 Sprinkler Protection
7.7.8.1 System Requirements,
A single line of sprinklers is permitted to protect a maximum of two stories of wall area or two levels of vertically aligned windows where ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 7 System Requirements > 7.7 Outside Sprinklers for Protection Against Exposure Fires (Exposure Protection Sprinkler Systems) > 7.7.8 Sprinklers > 7.7.8.1
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE