• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

913.2.1 Protection of Fire Pump Rooms

Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 913 Fire Pumps > 913.2 Protection Against Interruption of Service > 913.2.1 Protection of Fire Pump Rooms
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Fire pumps shall be located in rooms that are separated from all other areas of the building by 2-hour fire barriers constructed in accordance with Section 707 or 2-hour horizontal assemblies constructed in accordance with Section 711, or both.
Exceptions:
  1. In other than high-rise buildings, separation by 1-hour fire barriers constructed in accordance with Section 707 or 1-hour horizontal assemblies constructed in accordance with Section 711, or both, shall be permitted in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2.
  2. Separation is not required for fire pumps physically separated in accordance with NFPA 20.

Related Code Sections


913.2.1 Fire Protection and Life Safety Systems, Protection of Fire Pump Rooms
Fire pumps shall be located in rooms that are separated from all other areas of the building by 2-hour fire barriers constructed in accordance ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 913 Fire Pumps > 913.2 Protection Against Interruption of Service > 913.2.1 Protection of Fire Pump Rooms
913.2.1 Fire Protection and Life Safety Systems, Protection of Fire Pump Rooms
Fire pumps shall be located in rooms that are separated from all other areas of the building by 2-hour fire barriers constructed in accordance ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 913 Fire Pumps > 913.2 Protection Against Interruption of Service > 913.2.1 Protection of Fire Pump Rooms
902.1 Fire Protection and Life Safety Systems, Pump and Riser Room Size
Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size
902.1 Fire Protection and Life Safety Systems, Pump and Riser Room Size
Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size
902.1.3 Fire Protection and Life Safety Systems, Environment
Automatic sprinkler system riser rooms and fire pump rooms shall be maintained at a temperature of not less than 40°F (4°C). Heating units shall ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size > 902.1.3 Environment
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING