• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.164(d) Protection of Fire Detectors

OSHA 1910 General Industry > L Fire Protection > 1910.164 Fire Detection Systems > 1910.164(d) Protection of Fire Detectors
JUMP TO FULL CODE CHAPTER

1910.164(d)(1)

The employer shall assure that fire detection equipment installed outdoors or in the presence of corrosive atmospheres be protected from corrosion. The employer shall provide a canopy, hood, or other suitable protection for detection equipment requiring protection from the weather.

1910.164(d)(2)

The employer shall locate or otherwise protect detection equipment so that it is protected from mechanical or physical impact which might render it inoperable.

1910.164(d)(3)

The employer shall assure that detectors are supported independently of their attachment to wires or tubing.

Related Code Sections


1910.164(d) Fire Protection, Protection of Fire Detectors
The employer shall assure that fire detection equipment installed outdoors or in the presence of corrosive atmospheres be protected from corrosion ...
OSHA 1910 General Industry > L Fire Protection > 1910.164 Fire Detection Systems > 1910.164(d) Protection of Fire Detectors
Subpart L Fire Protection, App C - Fire Protection References for Further Information
Electrical Code, ANSI/NFPA 70; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Standard on Automatic Fire Detectors, ANSI/NFPA ...
OSHA 1910 General Industry > L Fire Protection > L App C - Fire Protection References for Further Information
Subpart L Fire Protection, App B - National Consensus Standards
National Standard, Practice for Respirator Protection for the Fire Service. ANSI/NFPA No. 1971, Protective Clothing for Structural Fire ...
OSHA 1910 General Industry > L Fire Protection > L App B - National Consensus Standards
1910.164(c) Fire Protection,
The employer shall assure that fire detectors and fire detection systems are tested and adjusted as often as needed ...
OSHA 1910 General Industry > L Fire Protection > 1910.164 Fire Detection Systems > 1910.164(c)
1910.164(c)(5) Fire Protection,
The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other particulates in order to be fully operational ...
OSHA 1910 General Industry > L Fire Protection > 1910.164 Fire Detection Systems > 1910.164(c) > 1910.164(c)(5)
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE