• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3307 Protection of Adjoining Property

Building Code 2021 of Illinois > 33 Safeguards During Construction > 3307 Protection of Adjoining Property
JUMP TO FULL CODE CHAPTER

[BS] 3307.1 Protection Required

Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runoff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoining buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation.

[BS] 3307.2 Excavation Retention Systems

Where a retention system is used to provide support of an excavation for protection of adjacent structures, the system shall conform to the requirements in Sections 3307.2.1 through 3307.2.3.

[BS] 3307.2.1 Excavation Retention System Design

Excavation retention systems shall be designed by a registered design professional to provide vertical and lateral support.

[BS] 3307.2.2 Excavation Retention System Monitoring

The retention system design shall include requirements for monitoring of the system and adjacent structures for horizontal and vertical movement.

[BS] 3307.2.3 Retention System Removal

Elements of the system shall only be removed or decommissioned where adequate replacement support is provided by backfill or by the new structure. Removal or decommissioning shall be performed in such a manner that protects the adjacent property.

Related Code Sections


Section 1502 Construction Safeguards, Protection of Adjoining Property
Adjoining public and private property shall be protected from damage during construction and demolition work. Protection must be provided ...
Existing Building Code 2018 of Illinois > 15 Construction Safeguards > 1502 Protection of Adjoining Property
Section 1502 Construction Safeguards, Protection of Adjoining Property
Adjoining public and private property shall be protected from damage during construction and demolition work. Protection must be provided ...
Existing Building Code 2021 of Illinois > 15 Construction Safeguards > 1502 Protection of Adjoining Property
Section 3307 Safeguards During Construction, Protection of Adjoining Property
Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall ...
Building Code 2021 of Illinois > 33 Safeguards During Construction > 3307 Protection of Adjoining Property
Section 3307 Safeguards During Construction, Protection of Adjoining Property
Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall ...
Building Code 2018 of Illinois > 33 Safeguards During Construction > 3307 Protection of Adjoining Property
3307.2 Safeguards During Construction, Excavation Retention Systems
or by the new structure. Removal or decommissioning shall be performed in such a manner that protects the adjacent property ...
Building Code 2021 of Illinois > 33 Safeguards During Construction > 3307 Protection of Adjoining Property > 3307.2 Excavation Retention Systems
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING