1609.1.2 Protection From Wind Borne Debris
JUMP TO FULL CODE CHAPTER
The following buildings shall be protected with an impact-resistant covering or glazing in accordance with the Missile Levels and Wind Zones specified in ASTM E 1886 and ASTM E 1996 or other approved test methods and performance criteria:
- Buildings in Structural Occupancy Category IV, as defined in Table 1604.5, located in Exposure C or D, as defined in Section 1609.4;
- Buildings in Structural Occupancy Category III, as defined in Table 1604.5, located in Exposure D, as defined in Section 1609.4, where the glazing of such building encloses places of assembly for 300 or more persons or areas of in-place shelter.
Louvers protecting intake and exhaust ventilation ducts not assumed to be open that are located within 30 feet (9144 mm) of grade shall meet the requirements of an approved impact-resisting standard or the large missile test of ASTM E 1996.
Garage door glazed opening protection for wind-borne debris shall meet the requirements of an approved impact-resisting standard or ANSI/DASMA 115.
Related Code Sections
1609.1.2 Structural Design, Protection From Wind Borne Debris
Garage door glazed opening protection for wind-borne debris shall meet the requirements of an approved impact ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.1 Applications > 1609.1.2 Protection From Wind Borne Debris
2407.1.4 Glass and Glazing, Glazing in Wind-Borne Debris Regions
Glazing installed in in-fill panels or balusters in wind-borne debris regions shall comply with the following ...
NYC Building Code 2014 > 24 Glass and Glazing > 2407 Glass in Handrails and Guards > 2407.1 Materials > 2407.1.4 Glazing in Wind-Borne Debris Regions
2304.11.11 Wood, Debris
All loose wood and debris and all wood forms shall be removed from spaces under the building. All stump and roots shall be grubbed to a minimum depth ...
NYC Building Code 2008 > 23 Wood > 2304 General Construction Requirements > 2304.11 Protection Against Decay and Termites > 2304.11.11 Debris
2304.11.11 Wood, Debris
All loose wood and debris and all wood forms shall be removed from spaces under the building. All stump and roots shall be grubbed to a minimum depth ...
NYC Building Code 2014 > 23 Wood > 2304 General Construction Requirements > 2304.11 Protection Against Decay and Termites > 2304.11.11 Debris
3314.8.2 Safeguards During Construction or Demolition, Debris Netting
Where required by Section 3314.8, the scaffold shall be enclosed with a debris netting consisting of a wire screen comprised of not less than number ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.8 Guardrail System and Debris Netting > 3314.8.2 Debris Netting