• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1109.4.1 Protection From Mechanical Damage

Los Angeles Mechanical Code > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.4 Location of Refrigeration Piping > 1109.4.1 Protection From Mechanical Damage
JUMP TO FULL CODE CHAPTER
Passages shall not be obstructed by refrigerant piping. Refrigerant piping shall not be located in an elevator, dumbwaiter, or other shaft containing a moving object, or in a shaft that has openings to living quarters, or to means of egress. Refrigerant piping shall not be installed in an enclosed public stairway, stair landing, or means of egress. [ASHRAE 15:8.10.2]

Related Code Sections


1109.4.1 Refrigeration, Protection From Mechanical Damage
Passages shall not be obstructed by refrigerant piping. Refrigerant piping shall not be located in an elevator, dumbwaiter, or other shaft containing ...
Los Angeles Mechanical Code > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.4 Location of Refrigeration Piping > 1109.4.1 Protection From Mechanical Damage
1109.4.1 Refrigeration, Protection From Mechanical Damage
Passages shall not be obstructed by refrigerant piping. Refrigerant piping shall not be located in an elevator, dumbwaiter, or other shaft containing ...
Los Angeles Mechanical Code > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.4 Location of Refrigeration Piping > 1109.4.1 Protection From Mechanical Damage
5505.1.2.4 Cryogenic Fluids, Physical Protection and Support
Piping systems shall be supported and protected from physical damage. Piping passing through walls shall be protected from mechanical damage ...
2017 LA City Fire Code > 55 Cryogenic Fluids > 5505 Use and Handling > 5505.1 General > 5505.1.2 Piping Systems > 5505.1.2.4 Physical Protection and Support
2310.3.3 Motor Fuel-Dispensing Facilities and Repair Garages, Hoses and Nozzles
be reeled, racked or otherwise protected from mechanical damage ...
2017 LA City Fire Code > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2310 Marine Motor Fuel-Dispensing Facilities > 2310.3 Dispensing > 2310.3.3 Hoses and Nozzles
R406.3.2 Foundations, Below-Grade Moisture Barrier
to the sheathing to form a seal. Film areas at grade level shall be protected from mechanical damage and exposure by a pressure-preservative treated lumber ...
Los Angeles Residential Code > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.3 Dampproofing for Wood Foundations > R406.3.2 Below-Grade Moisture Barrier
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE