// CODE SNIPPET
P3001.2 Protection From Freezing
JUMP TO FULL CODE CHAPTER
No portion of the above-grade DWV system, other than vent terminals, shall be located outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect them from freezing by insulation or heat or both, except in localities having a winter design temperature greater than 32°F (0°C) (ASHRAE 97.5 percent column, winter, see Chapter 3).
Related Code Sections
1402.5.3 Solar Systems, Protection From Freezing
System components shall be protected from damage by freezing of heat transfer liquids at the lowest ambient temperatures that will be encountered ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 14 Solar Systems > 1402 Installation > 1402.5 Equipment > 1402.5.3 Protection From Freezing
M2301.2.6 Solar Thermal Energy Systems, Protection From Freezing
System components shall be protected from damage resulting from freezing of heat-transfer liquids at the winter design temperature provided in Table ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 23 Solar Thermal Energy Systems > M2301 Thermal Solar Energy Systems > M2301.2 Design and Installation > M2301.2.6 Protection From Freezing
P3001.2 Sanitary Drainage, Protection From Freezing
in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect them from freezing ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 30 Sanitary Drainage > P3001 General > P3001.2 Protection From Freezing
P2904.2.3 Water Supply and Distribution, Freezing Areas
Piping shall be protected from freezing as required by Section P2603.5. Where sprinklers are required in areas that are subject to freezing, dry ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 29 Water Supply and Distribution > P2904 Dwelling Unit Fire Sprinkler Systems > P2904.2 Sprinklers > P2904.2.3 Freezing Areas
P3201.3 Traps, Trap Setting and Protection
Traps shall be set level with respect to their water seals and shall be protected from freezing. Trap seals shall be protected from siphonage ...