R606.13 Protection for Reinforcement
JUMP TO FULL CODE CHAPTER
Bars shall be completely embedded in mortar or grout. Joint reinforcement embedded in horizontal mortar joints shall not have less than 5/8-inch (15.9 mm) mortar coverage from the exposed face. All other reinforcement shall have a minimum coverage of one bar diameter over all bars, but not less than 3/4 inch (19 mm), except where exposed to weather or soil, in which case the minimum coverage shall be 2 inches (51 mm).
Related Code Sections
R606.13 Wall Construction, Protection for Reinforcement
Bars shall be completely embedded in mortar or grout. Joint reinforcement embedded in horizontal mortar joints shall not have less than 5 / 8 -inch ...
2012 IRC portion of the 2016 CT State Building Code > 6 Wall Construction > R606 General Masonry Construction > R606.13 Protection for Reinforcement
R606.3.4 Wall Construction, Protection for Reinforcement
). Minimum corrosion protection of joint reinforcement, anchor ties and wire ...
2015 IRC portion of the 2018 CT State Building Code > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.4 Protection for Reinforcement
704.7 Fire and Smoke Protection Features, Reinforcing
Thickness of protection for concrete or masonry reinforcement shall be measured to the outside of the reinforcement except that stirrups and spiral ...
2015 IBC portion of the 2018 CT State Building Code > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.7 Reinforcing
704.7 Fire and Smoke Protection Features, Reinforcing
Thickness of protection for concrete or masonry reinforcement shall be measured to the outside of the reinforcement except that stirrups and spiral ...
2012 IBC portion of the 2016 CT State Building Code > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.7 Reinforcing
721.1.3 Fire and Smoke Protection Features, Reinforcement for Cast-In-Place Concrete Column Protection
Cast-in-place concrete protection for steel columns shall be reinforced at the edges of such members with wire ties of not less than 0.18 inch (4.6 ...
2015 IBC portion of the 2018 CT State Building Code > 7 Fire and Smoke Protection Features > 721 Prescriptive Fire-Resistance > 721.1 General > 721.1.3 Reinforcement for Cast-In-Place Concrete Column Protection