305.6 Protection Against Physical Damage
JUMP TO FULL CODE CHAPTER
In concealed locations where piping, other than cast-iron or galvanized steel, is installed through holes or notches in studs, joists, rafters or similar members less than 11/2 inches (38 mm) from the nearest edge of the member, the pipe shall be protected by steel shield plates. Such shield plates shall have a thickness of not less than 0.0575 inch (1.463 mm) (No. 16 gage). Such plates shall cover the area of the pipe where the member is notched or bored, and shall extend not less than 2 inches (51 mm) above sole plates and below top plates.
Related Code Sections
230.50 Wiring and Protection, Protection Against Physical Damage
Underground service-entrance conductors shall be protected against physical damage in accordance with 300.5 ...
2017 North Carolina Electrical Code > 2 Wiring and Protection > 230 Services > 230.50 Protection Against Physical Damage
(C) General, Protection Against Physical Damage
Conductors and cables in tunnels shall be located above the tunnel floor and so placed or guarded to protect them from physical damage ...
2017 North Carolina Electrical Code > 1 General > 110 Requirements for Electrical Installations > 110.51 General > (C) Protection Against Physical Damage
225.20 Wiring and Protection, Protection Against Physical Damage
Conductors installed on buildings, structures, or poles shall be protected against physical damage as provided for services in 230.50 ...
2017 North Carolina Electrical Code > 2 Wiring and Protection > 225 Outside Branch Circuits and Feeders > 225.20 Protection Against Physical Damage
300.4 Wiring Methods and Materials, Protection Against Physical Damage
Where subject to physical damage, conductors, raceways, and cables shall be protected. Informational Note: Minor damage to a raceway, cable armor ...
2017 North Carolina Electrical Code > 3 Wiring Methods and Materials > 300 General Requirements for Wiring Methods and Materials > 300.4 Protection Against Physical Damage
305.5 General Regulations, Protection Against Physical Damage
members less than 1 1 / 2 inches (38 mm) from the nearest edge of the member, the pipe shall be protected by shield plates. Protective steel shield plates ...
2018 North Carolina Mechanical Code > 3 General Regulations > 305 Piping Support > 305.5 Protection Against Physical Damage