R404.1.3.3.4 Proportioning and Slump of Concrete
JUMP TO FULL CODE CHAPTER
Proportions of materials for concrete shall be established to provide workability and consistency to permit concrete to be worked readily into forms and around reinforcement under conditions of placement to be employed, without segregation or excessive bleeding. Slump of concrete placed in removable forms shall not exceed 6 inches (152 mm).
Exception: When approved, the slump is permitted to exceed 6 inches (152 mm) for concrete mixtures that are resistant to segregation, and are in accordance with the form manufacturer's recommendations.
Slump of concrete placed in stay-in-place forms shall exceed 6 inches (152 mm). Slump of concrete shall be determined in accordance with ASTM C 143.
Exception: When approved, the slump is permitted to exceed 6 inches (152 mm) for concrete mixtures that are resistant to segregation, and are in accordance with the form manufacturer's recommendations.
Slump of concrete placed in stay-in-place forms shall exceed 6 inches (152 mm). Slump of concrete shall be determined in accordance with ASTM C 143.
Related Code Sections
R404.1.3.3.4 Foundations, Proportioning and Slump of Concrete
Proportions of materials for concrete shall be established to provide workability and consistency to permit concrete to be worked readily into forms ...
MA State Building Code, 9th ed, Residential Volume > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.4 Proportioning and Slump of Concrete
R608.5.1.4 Wall Construction, Proportioning and Slump of Concrete
Proportions of materials for concrete shall be established to provide workability and consistency to permit concrete to be worked readily into forms ...
MA State Building Code, 9th ed, Residential Volume > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.1 Concrete and Materials for Concrete > R608.5.1.4 Proportioning and Slump of Concrete
1808.8.1 Soils and Foundations, Concrete or Grout Strength and Mix Proportioning
and proportioned so as to produce a cohesive workable mix having a slump of not less than 4 inches (102 mm) and not more than 8 inches (204 mm). Where concrete ...
MA State Building Code, 9th ed, Base Volume > 18 Soils and Foundations > 1808 Foundations > 1808.8 Concrete Foundations > 1808.8.1 Concrete or Grout Strength and Mix Proportioning
1808.8.1 Soils and Foundations, Concrete or Grout Strength and Mix Proportioning
and proportioned so as to produce a cohesive workable mix having a slump of not less than 4 inches (102 mm) and not more than 8 inches (204 mm). Where concrete ...
MA State Building Code, 8th ed, Base Volume > 18 Soils and Foundations > 1808 Foundations > 1808.8 Concrete Foundations > 1808.8.1 Concrete or Grout Strength and Mix Proportioning
1908.2 Concrete, Proportions and Materials
Shotcrete proportions shall be selected that allow suitable placement procedures using the delivery equipment selected and shall result in finished ...
MA State Building Code, 9th ed, Base Volume > 19 Concrete > 1908 Shotcrete > 1908.2 Proportions and Materials