• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

407.4.3 Projections in Nursing Home Corridors

Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.4 Means of Egress > 407.4.3 Projections in Nursing Home Corridors
JUMP TO FULL CODE CHAPTER
CALCULATE P
P Premium Feature

This feature is included in premium subscriptions only. Click below to start a free trial.

Start Free Trial
CALCULATE
Calculate code sheet portions referencing this topic.
In Group I-2, Condition 1 occupancies, where the corridor width is not less than 96 inches (2440 mm), projections shall be permitted for furniture where all of the following criteria are met:
  1. The furniture is attached to the floor or to the wall.
  2. The furniture does not reduce the clear width of the corridor to less than 72 inches (1830 mm) except where other encroachments are permitted in accordance with Section 1005.7.
  3. The furniture is positioned on only one side of the corridor.
  4. Each arrangement of furniture is 50 square feet (4.6 m2) maximum in area.
  5. Furniture arrangements are separated by 10 feet (3048 mm) minimum.
  6. Placement of furniture is considered as part of the fire and safety plans in accordance with Section 1002.2.

Related Code Sections


407.4.3 Special Detailed Requirements Based on Occupancy and Use, Projections in Nursing Home Corridors
In Group I-2, Condition 1 occupancies, where the corridor width is not less than 96 inches (2440 mm), projections shall be permitted for furniture ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.4 Means of Egress > 407.4.3 Projections in Nursing Home Corridors
407.4.3 Special Detailed Requirements Based on Occupancy and Use, Projections in Nursing Home Corridors
In Group I-2, Condition 1 occupancies, where the corridor width is not less than 96 inches (2440 mm), projections shall be permitted for furniture ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.4 Means of Egress > 407.4.3 Projections in Nursing Home Corridors
704.1.1 Alterations—Level 1, Projections in Nursing Home Corridors
In Group I-2, Condition 1 occupancies, where the corridor is at least 96 inches (2438 mm) wide, projections into the corridor width are permitted ...
Existing Building Code 2021 of Illinois > 7 Alterations—Level 1 > 704 Means of Egress > 704.1 General > 704.1.1 Projections in Nursing Home Corridors
517.40 Special Occupancies, Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
Informational Note: Nursing homes and other limited care facilities can be classified as critical care (Category 1) or general care (Category 2 ...
National Electrical Code 2017 of Illinois > 5 Special Occupancies > 517 Health Care Facilities > 517.40 Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
(B) Special Occupancies, Not Covered
, and outpatient facilities Areas of nursing homes and limited care facilities wired in accordance with Chapters 1 through 4 of this Code where these areas ...
National Electrical Code 2017 of Illinois > 5 Special Occupancies > 517 Health Care Facilities > 517.10 Applicability > (B) Not Covered
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING