• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3308.6.2.6 Projection of Nets

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.6 Horizontal Safety Netting Systems > 3308.6.2 Horizontal Safety Netting Systems Requirements > 3308.6.2.6 Projection of Nets
JUMP TO FULL CODE CHAPTER
The phrase, "as to capture falling personnel" in Section 10.6 of ANSI/ASSE A10.11 shall be amended to read "as to capture falling material."

Related Code Sections


3308.6.2.6 Safeguards During Construction or Demolition, Projection of Nets
The phrase, "as to capture falling personnel" in Section 10.6 of ANSI/ASSE A10.11 shall be amended to read "as to capture falling material ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.6 Horizontal Safety Netting Systems > 3308.6.2 Horizontal Safety Netting Systems Requirements > 3308.6.2.6 Projection of Nets
3308.2 Safeguards During Construction or Demolition, Horizontal Safety Netting Requirements
safety netting shall project outward horizontally from the edge of the floor a minimum distance of 10 feet (3048 mm) ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3308 Safety Netting > 3308.2 Horizontal Safety Netting Requirements
Appendix A Selected Rules of the Department of Buildings [PDF] (page 76)
shall develop the full strength of the net. (2) Projection of safety netting. Horizontal safety netting shall project outward horizontally from the edge ...
NYC 1968 Code (Vol II) [PDF] > A Selected Rules of the Department of Buildings
1609.6.3.1 Structural Design, Main Wind Force-Resisting System
Main wind force-resisting systems shall comply with the following: The building shall be designed for the following net lateral wind ...
NYC Building Code 2008 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.3 Simplified Design Procedure-II > 1609.6.3.1 Main Wind Force-Resisting System
1609.6.3.1 Structural Design, Main Wind-Force-Resisting System
Main wind force-resisting systems shall comply with the following: The building shall be designed for the following net lateral wind pressure ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.3 Simplified Design Procedure II > 1609.6.3.1 Main Wind-Force-Resisting System
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE