Where the fire separation distance on a lower floor is greater than the fire separation distance on the floor immediately above, the projecting floor shall have not less than the fire-resistance rating as the exterior wall above based on Table 602. The fire-resistant rating of the horizontal portion shall be continuous to the lower vertical wall.

Related Code Sections

705.2.5 Fire and Smoke Protection Features, Projecting Floors
Where the fire separation distance on a lower floor is greater than the fire separation distance on the floor immediately above, the projecting floor ...
M1408.3 Heating and Cooling Equipment and Appliances, Location
furnace register shall be located not less than 5 feet (1524 mm) below any projecting combustible materials. The floor furnace burner assembly shall ...
M1408.3 Heating and Cooling Equipment and Appliances, Location
furnace register shall be located not less than 5 feet (1524 mm) below any projecting combustible materials. The floor furnace burner assembly ...
1010.1.1.1 Means of Egress, Projections Into Clear Width
There shall not be projections into the required clear width lower than 34 inches (864 mm) above the floor or ground. Projections into the clear ...
1010.1.1.1 Means of Egress, Projections Into Clear Width
There shall not be projections into the required clear width lower than 34 inches (864 mm) above the floor or ground. Projections into the clear ...