• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3311.2 Projectile Tools

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools
JUMP TO FULL CODE CHAPTER
Projectile tools shall comply with the requirements of Sections 3311.2.1 through 3311.2.3.

3311.2.1 Basic Requirements

Design and construction of the tool must be such as to safely retain all internal pressures that may occur during its operation. The discharge mechanism shall be such that the projectile cannot be discharged by dropping the tool. The discharge mechanism shall be such that the discharge of each projectile shall be dependent on a separate and distinct act by the operator, and all safety features shall be durable.

A tool shall have such other characteristics as the commissioner may find necessary. Such other characteristics may include devices and materials external to the tool itself but associated with its function, and may also include, in respect to high velocity projectile tools, the basic requirements set forth above for explosive powered tools that discharge projectiles with comparable velocities.

3311.2.2 Maintenance

Every projectile tool shall be properly maintained. No such tool shall be used if any part necessary to retain internal pressures or to prevent accidental discharge of a projectile is not in sound and operable condition.

3311.2.3 Operation

The operation of projectile tools shall comply with the following:
  1. A projectile tool shall be operated only by an authorized operator who shall be the owner, lessee, or other person having custody of the tool, or any other person whom he or she may authorize to operate it.
  2. While a projectile tool is in the care and custody of an authorized operator, no other person shall handle or in any way utilize or modify it.
  3. No authorized operator of a projectile tool shall leave it unattended while it is in a condition to discharge a projectile.
  4. No person shall use a projectile tool for any purpose other than that for which it was manufactured.
  5. No person shall point a projectile tool at another person or hold it at an angle that allows the projectile to fly free.
  6. No person shall use a projectile tool in such a way as to endanger persons who may be in the vicinity.

Related Code Sections


3311.2 Safeguards During Construction or Demolition, Projectile Tools
mechanism shall be such that the projectile cannot be discharged by dropping the tool. The discharge mechanism shall be such that the discharge of each ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools
3311.2 Safeguards During Construction or Demolition, Projectile Tools
Projectile tools shall comply with the requirements of Sections 3311.2.1 through 3311.2.3 ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools
3311.2.1 Safeguards During Construction or Demolition, Basic Requirements
mechanism shall be such that the projectile cannot be discharged by dropping the tool. The discharge mechanism shall be such that the discharge of each ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools > 3311.2.1 Basic Requirements
3311.2.2 Safeguards During Construction or Demolition, Maintenance
Every projectile tool shall be properly maintained. No such tool shall be used if any part necessary to retain internal pressures or to prevent ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools > 3311.2.2 Maintenance
3311.2.2 Safeguards During Construction or Demolition, Maintenance
Every projectile tool shall be properly maintained. No such tool shall be used if any part necessary to retain internal pressures or to prevent ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3311 Explosive Powered and Projectile Tools > 3311.2 Projectile Tools > 3311.2.2 Maintenance
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE