• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

713.7.1 Prohibited Openings

Building Code 2015 of Utah > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.7 Openings > 713.7.1 Prohibited Openings
JUMP TO FULL CODE CHAPTER
Openings other than those necessary for the purpose of the shaft shall not be permitted in shaft enclosures.

Related Code Sections


713.7.1 Fire and Smoke Protection Features, Prohibited Openings
Openings other than those necessary for the purpose of the shaft shall not be permitted in shaft enclosures ...
Building Code 2018 of Utah > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.7 Openings > 713.7.1 Prohibited Openings
713.7.1 Fire and Smoke Protection Features, Prohibited Openings
Openings other than those necessary for the purpose of the shaft shall not be permitted in shaft enclosures ...
Building Code 2015 of Utah > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.7 Openings > 713.7.1 Prohibited Openings
307.1.1 General Requirements, Prohibited Open Burning
Open burning shall be prohibited when atmospheric conditions or local circumstances make such fires hazardous. Exception: Prescribed burning ...
Fire Code 2018 of Utah > 3 General Requirements > 307 Open Burning, Recreational Fires and Portable Outdoor Fireplaces > 307.1 General > 307.1.1 Prohibited Open Burning
406.3.4.2 Special Detailed Requirements Based on Use and Occupancy, Openings Prohibited
Openings from a private garage directly into a room used for sleeping purposes shall not be permitted ...
Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.3 Private Garages and Carports > 406.3.4 Separation > 406.3.4.2 Openings Prohibited
2105.1.3 Dry Cleaning, Open Systems Prohibited
Dry cleaning by immersion and agitation in open vessels shall be prohibited ...
Fire Code 2018 of Utah > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.3 Open Systems Prohibited
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE