405.0 Prohibited Fixtures
JUMP TO FULL CODE CHAPTER
Water closets having an invisible seal or an unventilated space or having walls which are not thoroughly washed at each discharge shall be prohibited. A water closet that might permit siphonage of the contents of the bowl back into the tank shall be prohibited.
Trough urinals and urinals with an invisible seal shall be prohibited.
Fixed wooden, or tile wash trays or sinks for domestic use shall not be installed in a building designed or used for human habitation. No sheet metal-lined wooden bathtub shall be installed or reconnected. No dry or chemical closet (toilet) shall be installed in a building used for human habitation unless first approved by the Health Officer.
Related Code Sections
405.0 Plumbing Fixtures and Fixture Fittings, Prohibited Fixtures
Water closets having an invisible seal or an unventilated space or having walls which are not thoroughly washed at each discharge shall be prohibited ...
2021 Oregon Plumbing Specialty Code > 4 Plumbing Fixtures and Fixture Fittings > 405.0 Prohibited Fixtures
1004.1 Traps and Interceptors, Prohibited
those of plastic, glass, or similar corrosion-resisting material, shall be used. "S" traps, bell traps, and crown-vented traps shall be prohibited. No ...
P3201.5 Traps, Prohibited Trap Designs
The following types of traps are prohibited: Bell traps. Separate fixture traps with interior partitions, except those lavatory traps made ...
2021 Oregon Residential Specialty Code (ORSC) > 32 Traps > P3201 Fixture Traps > P3201.5 Prohibited Trap Designs
P3109.2 Vents, Stack Installation
The waste stack shall be vertical, and both horizontal and vertical offsets shall be prohibited between the lowest fixture drain connection ...
2021 Oregon Residential Specialty Code (ORSC) > 31 Vents > P3109 Waste Stack Vent > P3109.2 Stack Installation
P3005.2.11 Sanitary Drainage, Prohibited Use
The use of a threaded cleanout opening to add a fixture or extend piping shall be prohibited except where another cleanout of equal size is installed ...
2021 Oregon Residential Specialty Code (ORSC) > 30 Sanitary Drainage > P3005 Drainage System > P3005.2 Cleanouts Required > P3005.2.11 Prohibited Use