• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1309.3.10.3 Prohibited Brazed Joints

California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.10 Inspection of Brazed Joints > 1309.3.10.3 Prohibited Brazed Joints
JUMP TO FULL CODE CHAPTER
Joints exhibiting the following conditions shall not be permitted:
  1. Flux or flux residue (where flux or flux-coated BAg series rods are used with dissimilar metals).
  2. Base metal melting or erosion.
  3. Unmelted filler metal.
  4. Failure of the filler metal to be clearly visible around the joint at the interface between the socket and the tube.
  5. Cracks in the tube or component.
  6. Cracks in the braze filler metal.
  7. Failure of the joint to hold the test pressure under the installer-performed initial pressure test in accordance with Section 1319.5 and the standing pressure test in accordance with Section 1319.7 or Section 1319.8. [NFPA 99:5.1.10.4.7.4, 5.3.6.10.4]

Related Code Sections


1309.10.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Prohibited Brazed Joints
the joint at the interface between the socket and the tube. Cracks in the tube or component. Cracks in the braze filler metal. Failure of the joint ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.10 Inspection of Brazed Joints > 1309.10.3 Prohibited Brazed Joints
1309.3.10.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Prohibited Brazed Joints
at the interface between the socket and the tube. Cracks in the tube or component. Cracks in the braze filler metal. Failure of the joint to hold ...
California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.10 Inspection of Brazed Joints > 1309.3.10.3 Prohibited Brazed Joints
605.1.1 Water Supply and Distribution, Brazed Joints
Brazed joints between copper or copper alloy pipe or tubing and fittings shall be made with brazing alloys having a liquid temperature above 1000°F ...
California Plumbing Code 2016 > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.1 Copper or Copper Alloy Pipe, Tubing, and Joints > 605.1.1 Brazed Joints
605.1.1 Water Supply and Distribution, Brazed Joints
Brazed joints between copper or copper alloy pipe or tubing and fittings shall be made with brazing alloys having a liquid temperature above 1000°F ...
California Plumbing Code 2019 > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.1 Copper or Copper Alloy Pipe, Tubing, and Joints > 605.1.1 Brazed Joints
705.3.1 Sanitary Drainage, Brazed Joints
Brazed joints between copper or copper alloy pipe and fittings shall be made with brazing alloys having a liquid temperature above 1000°F (538°C ...
California Plumbing Code 2016 > 7 Sanitary Drainage > 705.0 Joints and Connections > 705.3 Copper or Copper Alloy Pipe (DWV) and Joints > 705.3.1 Brazed Joints
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE