• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P-720.8 Private Use Fixtures

Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation > P-720.8 Private Use Fixtures
JUMP TO FULL CODE CHAPTER
All new and/or replacement plumbing fixtures for private use shall be of the water conservation type. These plumbing systems, or parts of systems, shall be equipped with water conservation equipment or devices which comply with the requirements of Sections P-720.8.1 through P-720.8.6.

P-720.8.1 Water Closet Tanks

Water closets equipped with tanks shall adequately flush and clean fixtures. These tanks shall discharge not more than 1.6 gallons per flush, and shall have a 1.6-gallon water level marker permanently affixed on the inside of the tank.

P-720.8.2 Other Fixtures

Lavatories, bathtubs, and other plumbing fixtures, shall be equipped with water conservation faucets or devices which control the volume of water so that it does not exceed three gallons per minute.

P-720.8.3 Showers

Showers and showerheads shall be equipped with an approved water conservation device, which controls the volume of water so that it does not exceed three gallons per minute.

P-720.8.4 Sinks

Sinks shall be equipped with an approved water conservation faucet or device, which controls the volume of water so that it does not exceed three gallons per minute.

P-720.8.5 Water Supply

The introduction of a new and/or replacement domestic water supply (water service) shall be controlled so that it does not exceed 60 pounds-per-square-inch (psi).

P-720.8.6 Other Use

Except as already provided for by the previous subsections, all new and/or replacement plumbing fixtures and all points of domestic water discharge shall be equipped with water conservation type devices which control the volume of water so that it does not exceed three gallons per

Related Code Sections


P-720.8 Plumbing Fixtures, Private Use Fixtures
All new and/or replacement plumbing fixtures for private use shall be of the water conservation type. These plumbing systems, or parts of systems ...
Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation > P-720.8 Private Use Fixtures
P-720.8.5 Plumbing Fixtures, Water Supply
The introduction of a new and/or replacement domestic water supply (water service) shall be controlled so that it does not exceed 60 pounds-per-square ...
Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation > P-720.8 Private Use Fixtures > P-720.8.5 Water Supply
P-720.1 Plumbing Fixtures, Definitions
Department or the Department of Licenses and Inspections. Private Use. Applies to plumbing fixtures not for use by the general public. Public Use ...
Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation > P-720.1 Definitions
P-720.4 Plumbing Fixtures, Swimming Pools
New swimming pools and/or alterations to plumbing fixtures in existing swimming pools for public or private use shall be equipped with a permanent ...
Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation > P-720.4 Swimming Pools
Section P-720 Plumbing Fixtures, Water Conservation
Department or the Department of Licenses and Inspections. Private Use. Applies to plumbing fixtures not for use by the general public. Public Use ...
Philadelphia Plumbing Code > 7 Plumbing Fixtures > P-720 Water Conservation
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE