• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

125-44 Private Street Requirements in Newtown Creek Subdistrict

NYC Zoning Resolution > XII Special Purpose Districts > 5 - Special Southern Hunters Point District (SHP) > 125-40 District Plan Elements > 125-44 Private Street Requirements in Newtown Creek Subdistrict
JUMP TO FULL CODE CHAPTER

In the Newtown Creek Subdistrict, where a private street is provided pursuant to paragraph (a) of Section 125-22, such private street shall be constructed to minimum Department of Transportation standards for public streets, including lighting, curbs and curb drops. Such private street shall consist of a paved road bed with a minimum width of 34 feet from curb to curb with 13 foot wide sidewalks on each side along its entire length. Such private street shall be located as shown on Map 8 (Publicly Accessible Private Street and Open Area in Newtown Creek Subdistrict) in Appendix A of this Chapter. One tree shall be planted for every 25 feet of curb length of the private street. Fractions equal to or greater than one-half resulting from this calculation shall be considered to be one tree. Such trees shall be planted at approximately equal intervals along the entire length of the curb of the private street.

Related Code Sections


Reference Standard 16 Plumbing and Gas Piping [PDF] (page 49)
(j) of this section, provided that no sewage shall be discharged into a street storm sewer; or (3) an existing private street storm sewer or private ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 16 Plumbing and Gas Piping
§27-948 Fire Alarm, Detection and Extinguishing Equipment, Installation of Private Fire Hydrants
two hundred fifty feet of a street hydrant; or, a private hydrant of the same type as the city hydrant connected to the street water main shall be provided ...
NYC 1968 Code (Vol I) > 17 Fire Alarm, Detection and Extinguishing Equipment > 3 Standpipe Requirements > §27-948 Installation of Private Fire Hydrants
Reference Standard 16 Plumbing and Gas Piping [PDF] (page 47)
to an intercepting sewer, a private sewage disposal system or some other point of disposal; (18) "Street sewer" means a sewer located in the bed of a street ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 16 Plumbing and Gas Piping
Article 3 Plumbing and Gas Piping, Drainage Systems
private sewage disposal system shall be installed in accordance with the requirements of this subchapter. When public sewers are made available ...
NYC 1968 Code (Vol I) > 16 Plumbing and Gas Piping > 3 Drainage Systems
305.5 General Regulations, Private Garages
Appliances located in private garages shall be installed with a minimum clearance of 6 feet (1829 mm) above the floor.    Exception: The ...
NYC Fuel Gas Code 2008 > 3 General Regulations > 305 Installation > 305.5 Private Garages
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE