• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

K 105.9 Primary Tank Outlets

Uniform Plumbing Code 2018 of Nevada > K Potable Rainwater Catchment Systems > K 105.0 Rainwater Storage Tanks > K 105.9 Primary Tank Outlets
JUMP TO FULL CODE CHAPTER
The primary tank outlet shall be located not less than 4 inches (102 mm) above the bottom of the tank, or shall be provided with a floating inlet to draw water from the cistern just below the water surface.
K 105.10 Storage Tank Venting. Where venting using drainage or overflow piping is not provided or is considered insufficient, a vent shall be installed on each tank. The vent shall extend from the top of the tank and terminate not less than 6 inches (152 mm) above grade and shall be not less than 11/2 inches (40 mm) in diameter. The vent terminal shall be directed downward and covered with a 3/32 of an inch (2.4 mm) mesh screen to prevent the entry of vermin and insect.
K 105.11 Pumps. Pumps serving rainwater catchment systems shall be listed for potable water use. Pumps supplying water to water closets, urinals, and trap primers shall be capable of delivering not less than 15 pounds-force per square inch (psi) (103 kPa) residual pressure at the highest and most remote outlet served. Where the water pressure in the rainwater supply system within the building exceeds 80 psi (552 kPa), a pressure reducing valve reducing the pressure to 80 psi (552 kPa) or less to water outlets in the building shall be installed in accordance with this code.
K 105.12 Roof Drains. Primary and secondary roof drains, conductors, leaders, overflows, and gutters shall be designed and installed in accordance with this code.

Related Code Sections


K 105.9 Potable Rainwater Catchment Systems, Primary Tank Outlets
The primary tank outlet shall be located not less than 4 inches (102 mm) above the bottom of the tank, or shall be provided with a floating inlet ...
Uniform Plumbing Code 2018 of Nevada > K Potable Rainwater Catchment Systems > K 105.0 Rainwater Storage Tanks > K 105.9 Primary Tank Outlets
P2911.7.3 Water Supply and Distribution, Outlets
Outlets shall be located not less than 4 inches (102 mm) above the bottom of the storage tank, and shall not skim water from the surface ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2911 On-Site Nonpotable Water Reuse Systems > P2911.7 Storage Tanks > P2911.7.3 Outlets
P2912.10.3 Water Supply and Distribution, Outlets
Outlets shall be located not less than 4 inches (102 mm) above the bottom of the storage tank and shall not skim water from the surface ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2912 Nonpotable Rainwater Collection and Distribution Systems > P2912.10 Storage Tanks > P2912.10.3 Outlets
1509.3 Roof Assemblies and Rooftop Structures, Tanks
In the bottom or on the side near the bottom of the tank, a pipe or outlet, fitted with a suitable quick-opening valve for discharging the contents ...
Building Code 2012 of Nevada > 15 Roof Assemblies and Rooftop Structures > 1509 Rooftop Structures > 1509.3 Tanks
1510.3 Roof Assemblies and Rooftop Structures, Tanks
In the bottom or on the side near the bottom of the tank, a pipe or outlet, fitted with a suitable quick-opening ...
Building Code 2018 of Nevada > 15 Roof Assemblies and Rooftop Structures > 1510 Rooftop Structures > 1510.3 Tanks
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING