• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

43.7.3 Prevention of Contamination

Fire Code 2018 of West Virginia > 43 Spraying, Dipping, and Coating Using Flammable or Combustible Materials > 43.7 Organic Peroxides and Plural Component Coatings > 43.7.3 Prevention of Contamination
JUMP TO FULL CODE CHAPTER
Measures shall be taken to prevent the contamination of organic peroxide formulations with any foreign substance. Only spray guns and related handling equipment that are specifically manufactured for use with organic peroxide formulations shall be used. Separate fluid-handling equipment shall be used for the resin and for the catalyst, and they shall not be interchanged. [33:16.3]

43.7.3.1

The wetted portions of equipment and apparatus that handle organic peroxide formulations shall be constructed of stainless steel (300 series), polyethylene, Teflon®, or other materials that are specifically recommended for the application. [33:16.3.1]

43.7.3.2*

Measures shall be taken to prevent contamination of organic peroxide formulations with dusts or overspray residues resulting from the sanding or spray application of finishing materials. [33:16.3.2]

43.7.3.3

Spills of organic peroxide formulations shall be promptly removed so there are no residues. Spilled material shall be permitted to be absorbed by use of a noncombustible absorbent, which is then disposed of promptly in accordance with the manufacturer's recommendations. [33:16.3.3]

Related Code Sections


43.7.3 Spraying, Dipping, and Coating Using Flammable or Combustible Materials, Prevention of Contamination
Measures shall be taken to prevent the contamination of organic peroxide formulations with any foreign substance. Only spray guns and related ...
Fire Code 2018 of West Virginia > 43 Spraying, Dipping, and Coating Using Flammable or Combustible Materials > 43.7 Organic Peroxides and Plural Component Coatings > 43.7.3 Prevention of Contamination
601.4 Duct Systems, Contamination Prevention
Exhaust ducts under positive pressure, chimneys and vents shall not extend into or pass through ducts or plenums. Exceptions: Exhaust ...
Mechanical Code 2015 of West Virginia > 6 Duct Systems > 601 General > 601.4 Contamination Prevention
1303.3 Nonpotable Water Systems, Debris Excluders
Downspouts and leaders shall be connected to a roof washer and shall be equipped with a debris excluder or equivalent device to prevent ...
Plumbing Code 2015 of West Virginia > 13 Nonpotable Water Systems > 1303 Nonpotable Rainwater Collection and Distribution Systems > 1303.3 Debris Excluders
P2912.3 Water Supply and Distribution, Debris Excluders
Downspouts and leaders shall be connected to a roof washer and shall be equipped with a debris excluder or equivalent device to prevent ...
Residential Code 2015 of West Virginia > 29 Water Supply and Distribution > P2912 Nonpotable Rainwater Collection and Distribution Systems > P2912.3 Debris Excluders
66.27.8.2.12.1 Flammable and Combustible Liquids,
Float-type check valves installed in tank openings connected to manifolded vent piping to prevent product contamination shall be permitted to be used ...
Fire Code 2018 of West Virginia > 66 Flammable and Combustible Liquids > 66.27 Piping Systems > 66.27.8 Vent Piping > 66.27.8.2 Vent Piping for Underground Tanks > 66.27.8.2.12 > 66.27.8.2.12.1
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING