• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1407(b) Preventing Encroachment/Electrocution

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(b) Preventing Encroachment/Electrocution
JUMP TO FULL CODE CHAPTER
Where encroachment precautions are required under Option (2), or Option (3) of this section, all of the following requirements must be met:

1926.1407(b)(1)

Conduct a planning meeting with the Assembly/Disassembly director (A/D director), operator, assembly/disassembly crew and the other workers who will be in the assembly/disassembly area to review the location of the power line(s) and the steps that will be implemented to prevent encroachment/electrocution.

1926.1407(b)(2)

If tag lines are used, they must be nonconductive.

1926.1407(b)(3)

At least one of the following additional measures must be in place. The measure selected from this list must be effective in preventing encroachment.

The additional measures are:

1926.1407(b)(3)(i)

Use a dedicated spotter who is in continuous contact with the equipment operator. The dedicated spotter must:

1926.1407(b)(3)(i)(A)

Be equipped with a visual aid to assist in identifying the minimum clearance distance. Examples of a visual aid include, but are not limited to: A clearly visible line painted on the ground; a clearly visible line of stanchions; a set of clearly visible line-of-sight landmarks (such as a fence post behind the dedicated spotter and a building corner ahead of the dedicated spotter).

1926.1407(b)(3)(i)(B)

Be positioned to effectively gauge the clearance distance.

1926.1407(b)(3)(i)(C)

Where necessary, use equipment that enables the dedicated spotter to communicate directly with the operator.

1926.1407(b)(3)(i)(D)

Give timely information to the operator so that the required clearance distance can be maintained.

1926.1407(b)(3)(iii)

A device that automatically warns the operator when to stop movement, such as a range control warning device. Such a device must be set to give the operator sufficient warning to prevent encroachment.

1926.1407(b)(3)(iv)

A device that automatically limits range of movement, set to prevent encroachment.

1926.1407(b)(3)(v)

An elevated warning line, barricade, or line of signs, in view of the operator, equipped with flags or similar high-visibility markings.

1926.1407(b)(3)(ii)

A proximity alarm set to give the operator sufficient warning to prevent encroachment.

Related Code Sections


1926.1407(b) Cranes & Derricks in Construction, Preventing Encroachment/Electrocution
of the power line(s) and the steps that will be implemented to prevent encroachment/electrocution ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(b) Preventing Encroachment/Electrocution
1926.1408(b) Cranes & Derricks in Construction, Preventing Encroachment/Electrocution
encroachment/electrocution. If tag lines are used ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1408 Power Line Safety (Up to 350 KV)--Equipment Operations > 1926.1408(b) Preventing Encroachment/Electrocution
1926.1407(b)(3)(ii) Cranes & Derricks in Construction,
A proximity alarm set to give the operator sufficient warning to prevent encroachment ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(b) Preventing Encroachment/Electrocution > 1926.1407(b)(3) > 1926.1407(b)(3)(ii)
1926.1407(b)(3)(iii) Cranes & Derricks in Construction,
the operator sufficient warning to prevent encroachment ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(b) Preventing Encroachment/Electrocution > 1926.1407(b)(3) > 1926.1407(b)(3)(iii)
1926.1407(b)(2) Cranes & Derricks in Construction,
If tag lines are used, they must be nonconductive ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(b) Preventing Encroachment/Electrocution > 1926.1407(b)(2)
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE