3305.3.5.3 Prestressed Members
JUMP TO FULL CODE CHAPTER
Form supports for prestressed concrete members shall not be removed until sufficient prestressing has been applied to prestressed members to carry their dead load and anticipated construction loads.
Related Code Sections
1906.5.3 Concrete, Prestressed Members
Form supports for prestressed concrete members shall not be removed until sufficient prestressing has been applied to prestressed members to carry ...
NYC Building Code 2008 > 19 Concrete > 1906 Formwork, Embedded Pipes and Construction Joints > 1906.5 Removal of Forms and Shoring > 1906.5.3 Prestressed Members
3305.3.5.3 Safeguards During Construction or Demolition, Prestressed Members
Form supports for prestressed concrete members shall not be removed until sufficient prestressing has been applied to prestressed members to carry ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3305 Material Placement and Installation > 3305.3 Concrete Formwork > 3305.3.5 Removal of Forms and Shoring > 3305.3.5.3 Prestressed Members
106.7.6 Administration, Pre-Stressing Forces
Where prestressed members are employed, a schedule or table shall show the total prestressing forces and the method and sequence of application ...
NYC Building Code 2008 > 1 Administration > 106 Construction Documents > 106.7 Structural Plans > 106.7.6 Pre-Stressing Forces
1908.1.3 Concrete, ACI 318, Section 21
in flexural members of frames, provided the average prestress, f pc , calculated for an area equal to the member's shortest cross-sectional dimension ...
NYC Building Code 2008 > 19 Concrete > 1908 Modifications to ACI 318 > 1908.1 General > 1908.1.3 ACI 318, Section 21
107.7.6 Administration, Prestressing Forces
Where pre-stressed members are employed, a schedule or table shall show the total prestressing forces and the method and sequence of application ...
NYC Building Code 2014 > 1 Administration > 107 Construction Documents > 107.7 Structural Plans > 107.7.6 Prestressing Forces