• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5807.1.5.3 Pressure Relief Device Marking

California Fire Code 2019 > 58 Flammable Gases and Flammable Cryogenic Fluids > 5807 Metal Hydride Storage Systems > 5807.1 General Requirements > 5807.1.5 Marking and Labeling > 5807.1.5.3 Pressure Relief Device Marking
JUMP TO FULL CODE CHAPTER

Metal hydride storage system pressure relief devices shall be marked with all of the following:

  1. Manufacturer's name.
  2. Metal hydride service in which the device can be used, or a product code that is traceable to this information.
  3. Activation parameters to include temperature, pressure or both.

5807.1.5.3.1 Pressure Relief Devices Integral to Container Valves

The required markings for pressure relief devices that are integral components of valves used on cylinders, containers and tanks shall be allowed to be placed on the valve.

Related Code Sections


5807.1.5.3 Flammable Gases and Flammable Cryogenic Fluids, Pressure Relief Device Marking
Metal hydride storage system pressure relief devices shall be marked with all of the following: Manufacturer's name. Metal hydride service ...
California Fire Code 2019 > 58 Flammable Gases and Flammable Cryogenic Fluids > 5807 Metal Hydride Storage Systems > 5807.1 General Requirements > 5807.1.5 Marking and Labeling > 5807.1.5.3 Pressure Relief Device Marking
5807.1.5.3 Flammable Gases and Flammable Cryogenic Fluids, Pressure Relief Device Marking
Metal hydride storage system pressure relief devices shall be marked with all of the following: Manufacturer's name. Metal hydride service ...
California Fire Code 2016 > 58 Flammable Gases and Flammable Cryogenic Fluids > 5807 Metal Hydride Storage Systems > 5807.1 General Requirements > 5807.1.5 Marking and Labeling > 5807.1.5.3 Pressure Relief Device Marking
1115.4 Refrigeration, Marking of Pressure-Relief Devices
Section VIII. Pressure-relief valves shall be marked by the manufacturer or assembler with the data required in accordance with ASME BPVC Section ...
California Mechanical Code 2016 > 11 Refrigeration > 1115.0 Labeling and Identification > 1115.4 Marking of Pressure-Relief Devices
1115.4 Refrigeration, Marking of Pressure-Relief Devices
Section VIII. Pressure-relief valves shall be marked by the manufacturer or assembler with the data required in accordance with ASME BPVC Section ...
California Mechanical Code 2019 > 11 Refrigeration > 1115.0 Labeling and Identification > 1115.4 Marking of Pressure-Relief Devices
1115.4.1 Refrigeration, Rupture Members
Rupture members for refrigerant pressure vessels shall be marked with the data required in accordance with ASME BPVC Section VIII. [ASHRAE 15:9.6.2] ...
California Mechanical Code 2019 > 11 Refrigeration > 1115.0 Labeling and Identification > 1115.4 Marking of Pressure-Relief Devices > 1115.4.1 Rupture Members
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE