605.1.3.2 Pressed Fittings
JUMP TO FULL CODE CHAPTER
Pressed fittings for copper or copper alloy pipe or tubing shall have an elastomeric o-ring that forms the joint. The pipe or
tubing shall be fully inserted into the fitting, and
the pipe or tubing marked at the shoulder of the fitting.
Pipe or tubing shall be cut square, chamfered,
and reamed to full inside diameter. The fitting
alignment shall be checked against the mark on the
pipe or tubing to ensure the pipe or tubing is
inserted into the fitting. The joint shall be pressed
using the tool recommended by the manufacturer.
Related Code Sections
605.1.3.2 Water Supply and Distribution, Pressed Fittings
Pressed fittings for copper or copper alloy pipe or tubing shall have an elastomeric o-ring that forms the joint. The pipe or
tubing shall be fully ...
California Plumbing Code 2016 > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.1 Copper or Copper Alloy Pipe, Tubing, and Joints > 605.1.3 Mechanical Joints > 605.1.3.2 Pressed Fittings
605.1.3.2 Water Supply and Distribution, Press-Connect Fittings
Press-connect
fittings for copper or copper alloy pipe or tubing
shall have an elastomeric o-ring that forms the
joint. The pipe or tubing shall ...
California Plumbing Code 2019 > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.1 Copper or Copper Alloy Pipe, Tubing, and Joints > 605.1.3 Mechanical Joints > 605.1.3.2 Press-Connect Fittings
4.2.2 Installation Standard for PEX Tubing Systems for Hot-And Cold-Water Distribution, Crimp or Press Insert Fittings
Crimp or press insert fittings typically
are made of brass, stainless steel, or
sulfone;
consist of an insert and a copper crimp
ring ...
California Plumbing Code 2016 > I Installation Standard for PEX Tubing Systems for Hot-And Cold-Water Distribution > 4.0 General > 4.2 Fittings > 4.2.2 Crimp or Press Insert Fittings
705.6.1 Sanitary Drainage, Mechanical Joints
Mechanical joints between stainless steel pipe and fittings shall be of the compression,
grooved coupling, hydraulic pressed fittings, or
flanged ...
California Plumbing Code 2016 > 7 Sanitary Drainage > 705.0 Joints and Connections > 705.6 Stainless Steel Pipe and Joints > 705.6.1 Mechanical Joints
705.7.1 Sanitary Drainage, Mechanical Joints
Mechanical joints
between stainless steel pipe and fittings shall be of the
compression, grooved coupling, hydraulic press-connect
fittings ...
California Plumbing Code 2019 > 7 Sanitary Drainage > 705.0 Joints and Connections > 705.7 Stainless Steel Pipe and Joints > 705.7.1 Mechanical Joints