P2906.19 Press-Connected Joints
Go To Full Code Chapter
Press-connected joints shall conform to one of the standards indicated in Table P2906.6. Press-type mechanical joints in copper tubing shall be made in accordance with the manufacturer's instructions. Cut tube ends shall be reamed to the full inside diameter of the tube end. Joint surfaces shall be cleaned. The tube shall be fully inserted into the press-connected fitting. Press-connected joints shall be pressed with a tool certified by the manufacturer.
Related Code Sections
1108.3.2.2 Refrigeration, Press-Connect Joints
Press-connect joints shall be installed in accordance with the manufacturer's instructions ...
1203.6.3 Hydronic Piping, Press-Connect Joints
Press-connect joints shall be installed in accordance with the manufacturer's instructions ...
1203.6.3 Hydronic Piping, Press-Connect Joints
Press-connect joints shall be installed in accordance with the manufacturer's instructions ...
1303.3.5 Fuel Oil Piping and Storage, Press-Connect Joints
Press-connect joints shall be installed in accordance with the manufacturer's instructions and shall conform to one of the standards listed in Table ...
605.13.5 Water Supply and Distribution, Press-Connect Joints
Press-connect joints shall conform to one of the standards indicated in Table 605.5, and shall be installed in accordance with the manufacturer's ...