206.2.7 Press Boxes
JUMP TO FULL CODE CHAPTER
Press boxes in assembly areas shall be on an accessible route.
EXCEPTIONS:
- An accessible route shall not be required to press boxes in bleachers that have points of entry at only one level provided that the aggregate area of all press boxes is 500 square feet (46 m2) maximum.
- An accessible route shall not be required to free-standing press boxes that are elevated above grade 12 feet (3660 mm) minimum provided that the aggregate area of all press boxes is 500 square feet (46 m2) maximum.
Advisory 206.2.7 Press Boxes Exception 2. Where a facility contains multiple assembly areas, the aggregate area of the press boxes in each assembly area is to be calculated separately. For example, if a university has a soccer stadium with three press boxes elevated 12 feet (3660 mm) or more above grade and each press box is 150 square feet (14 m2), then the aggregate area of the soccer stadium press boxes is less than 500 square feet (46 m2) and Exception 2 applies to the soccer stadium. If that same university also has a football stadium with two press boxes elevated 12 feet (3660 mm) or more above grade and one press box is 250 square feet (23 m2), and the second is 275 square feet (26 m2), then the aggregate area of the football stadium press boxes is more than 500 square feet (46 m2) and Exception 2 does not apply to the football stadium.
Related Code Sections
206.2.7 Scoping Requirements, Press Boxes
Press boxes in assembly areas shall be on an accessible route.
EXCEPTIONS :
An accessible route shall not be required to press boxes ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.2 Where Required > 206.2.7 Press Boxes
221.2.1.3 Scoping Requirements, Other Boxes
In boxes other than those required to comply with 221.2.1.2, the total number of wheelchair spaces required shall be determined in accordance ...
2010 ADA Standards > 2 Scoping Requirements > 221 Assembly Areas > 221.2 Wheelchair Spaces > 221.2.1 Number and Location > 221.2.1.3 Other Boxes
228.2 Scoping Requirements, Mail Boxes
Where mail boxes are provided in an interior location, at least 5 percent, but no fewer than one, of each type shall comply with 309. In ...
2010 ADA Standards > 2 Scoping Requirements > 228 Depositories, Vending Machines, Change Machines, Mail Boxes, and Fuel Dispensers > 228.2 Mail Boxes
1004 Recreation Facilities, Exercise Machines and Equipment
greatly depending on the use of the equipment or machine. For example, to provide access to a shoulder press machine, clear floor space next ...
203.13 Scoping Requirements, Raised Boxing or Wrestling Rings
Raised boxing or wrestling rings shall not be required to comply with these requirements or to be on an accessible route ...
2010 ADA Standards > 2 Scoping Requirements > 203 General Exceptions > 203.13 Raised Boxing or Wrestling Rings