// CODE SNIPPET
A4.601.4.2 Prerequisite and Elective Measures for Tier 1
JUMP TO FULL CODE CHAPTER
In addition to the mandatory measures, compliance with the following prerequisite and elective measures from Appendix A4 is also required to achieve Tier 1 status:
From Division A4.1, Planning and Design.
- 1.1. Comply with the topsoil protection requirements in Section A4.106.2.3.
- 1.2. Comply with the 20 percent permeable paving requirements in Section A4.106.4.
- 1.3. Comply with the cool roof requirements in Section A4.106.5.
- 1.4. Comply with the electric vehicle (EV) charging requirements in Section A4.106.8.
- 1.5. Comply with at least two elective measures selected from Division A4.1.
From Division A4.2, Energy Efficiency.
- 2.1. For newly constructed low-rise residential buildings, comply with the energy efficiency requirements in Section A4.203.1.1 and A4.203.1.2.1.
- 2.2. For additions to low-rise residential buildings, comply with the energy efficiency requirements in Section A4.204.1.1.
From Division A4.3, Water Efficiency and Conservation.
- 3.1. Comply with at least two elective measures selected from Division A4.3.
From Division A4.4, Material Conservation and Resource Efficiency.
- 4.1. Comply with the 20 percent cement reduction requirements in Section A4.403.2.
- 4.2. Comply with the 10 percent recycled content requirements in Section A4.405.3.1.
- 4.3. Comply with the 65 percent reduction in construction waste in Section A4.408.1.
- 4.4. Comply with at least two elective measures selected from Division A4.4.
From Division A4.5, Environmental Quality.
- 5.1. Comply with the 90-percent resilient flooring systems requirements in Section A4.504.2.
- 5.2. Comply with the thermal insulation requirements for Tier 1 in Section A4.504.3.
- 5.3. Comply with at least one elective measure selected from Division A4.5.
Note: The Residential Occupancies Application Checklist contained in Section A4.602 may be used to show which elective measures are selected.
Related Code Sections
A4.601.4.2 Residential Voluntary Measures, Prerequisite and Elective Measures for Tier 1
with the Tier 1 electric vehicle (EV) charging requirements in Section A4.106.8.
Comply with at least two elective measures selected from Division A4.1 ...
Los Angeles Green Building Code > A4 Residential Voluntary Measures > A4.601 General > A4.601.4 Tier 1 > A4.601.4.2 Prerequisite and Elective Measures for Tier 1
A4.601.4.2 Residential Voluntary Measures, Prerequisite and Elective Measures for Tier 1
requirements for Tier 1 in Section A4.504.3. 5.3. Comply with at least one elective measure selected from Division A4.5. Note: The Residential ...
Los Angeles Green Building Code > A4 Residential Voluntary Measures > A4.601 General > A4.601.4 Tier 1 > A4.601.4.2 Prerequisite and Elective Measures for Tier 1
A5.602.1 Nonresidential Voluntary Measures, CALGreen Verification Guidelines Tier 1 Checklist
a "Y" on the selected
elective and add an "N" on the rest.
Count the total number of Tier 1 prerequisite measures plus the additional electives ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist > A5.602.1 CALGreen Verification Guidelines Tier 1 Checklist
A5.602.1 Nonresidential Voluntary Measures, CALGreen Verification Guidelines Tier 1 Checklist
a "Y" on the selected
elective and add an "N" on the rest.
Count the total number of Tier 1 prerequisite measures plus the additional electives ...
Los Angeles Green Building Code > A5 Nonresidential Voluntary Measures > A5.602 CALGreen Verification Guidelines Mandatory Measures Checklist > A5.602.1 CALGreen Verification Guidelines Tier 1 Checklist
A4.601.5.2 Residential Voluntary Measures, Prerequisite and Elective Measures for Tier 2
with the thermal insulation requirements for Tier 1 and Tier 2 in Section A4.504.3. 5.3. Comply with at least one elective measure selected from ...
Los Angeles Green Building Code > A4 Residential Voluntary Measures > A4.601 General > A4.601.5 Tier 2 > A4.601.5.2 Prerequisite and Elective Measures for Tier 2