• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

AS106.12.1 Precompression of Load-Bearing Strawbale Walls

2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.12 Load-Bearing Walls > AS106.12.1 Precompression of Load-Bearing Strawbale Walls
JUMP TO FULL CODE CHAPTER
Prior to application of plaster, walls designed to be load bearing shall be precompressed by a uniform load of not less than 100 plf (1459 N/m).

Related Code Sections


AS106.12.1 Strawbale Construction, Precompression of Load-Bearing Strawbale Walls
Prior to application of plaster, walls designed to be load bearing shall be precompressed by a uniform load of not less than 100 plf (1459 N/m) ...
2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.12 Load-Bearing Walls > AS106.12.1 Precompression of Load-Bearing Strawbale Walls
Section AS102 Strawbale Construction, Definitions
parallel with the wall plane, its ties concealed in the unfinished wall and its straw lengths oriented across the thickness of the wall. LOAD-BEARING ...
2015 Michigan Residential Code > S Strawbale Construction > AS102 Definitions
AS106.6 Strawbale Construction, Plaster on Structural Walls
Plaster on load-bearing walls shall be in accordance with Table AS106.12. Plaster on shear walls shall be in accordance with Table AS106.13(1 ...
2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.6 Plaster on Structural Walls
AS105.4 Strawbale Construction, Out-Of-Plane Resistance and Unrestrained Wall Dimensions
approved vertical restraints. For load-bearing walls, H refers to vertical height only. T = Bale thickness in feet (mm). Plaster reinforcement ...
2015 Michigan Residential Code > S Strawbale Construction > AS105 Strawbale Walls-General > AS105.4 Out-Of-Plane Resistance and Unrestrained Wall Dimensions
Section AS105 Strawbale Construction, Strawbale Walls-General
(mm) between approved vertical restraints. For load-bearing walls, H refers to vertical height only. T = Bale thickness in feet (mm). Plaster ...
2015 Michigan Residential Code > S Strawbale Construction > AS105 Strawbale Walls-General
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE