• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3308.9.2 Precautions

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.9 Unenclosed Perimeter Protection Inspection, Use, Adjustment, Maintenance, and Repair > 3308.9.2 Precautions
JUMP TO FULL CODE CHAPTER
Precautions shall be taken to prevent safety net systems, guardrail systems, and alternative systems authorized under Section 3308.8 from being damaged by sunlight, abrasion, sand, rust, welding, cutting operations, chemicals, and airborne contaminants, where such systems are susceptible to damage by such.

Related Code Sections


1905.6.5.1 Concrete, Precaution
If any strength test of laboratory-cured cylinders performed in accordance with Section 1905.6.2.4 falls below the specified value of f' c ...
NYC Building Code 2008 > 19 Concrete > 1905 Concrete Quality, Mixing and Placing > 1905.6 Evaluation and Acceptance of Concrete > 1905.6.5 Low-Strength Test Results > 1905.6.5.1 Precaution
1905.6.5.1 Concrete, Precaution
If any strength test of laboratory-cured cylinders performed in accordance with Section 1905.6.2.4 falls below the specified value of f' c by more ...
NYC Building Code 2014 > 19 Concrete > 1905 Concrete Quality, Mixing and Placing > 1905.6 Evaluation and Acceptance of Concrete > 1905.6.5 Low-Strength Test Results > 1905.6.5.1 Precaution
3308.9.2 Safeguards During Construction or Demolition, Precautions
Precautions shall be taken to prevent safety net systems, guardrail systems, and alternative systems authorized under Section 3308.8 from being ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.9 Unenclosed Perimeter Protection Inspection, Use, Adjustment, Maintenance, and Repair > 3308.9.2 Precautions
3109.3.3 Special Construction, Electrical Precautions
No overhead electrical conductors shall be installed within 15 feet (4572 mm) of any swimming pool. All metal fences, enclosures, or railings ...
NYC Building Code 2008 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.3 All Swimming Pools > 3109.3.3 Electrical Precautions
3109.3.4 Special Construction, Electrical Precautions
No overhead electrical conductors shall be installed within 15 feet (4572 mm) of any swimming pool. All metal fences, enclosures, or railings ...
NYC Building Code 2014 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.3 Pool Safety and Accessibility > 3109.3.4 Electrical Precautions
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE