• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R406.4 Precast Concrete Foundation System Dampproofing

Minnesota Residential Code 2015 > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.4 Precast Concrete Foundation System Dampproofing
JUMP TO FULL CODE CHAPTER
Except where required by Section R406.2 to be waterproofed, precast concrete foundation walls enclosing habitable or useable spaces located below grade shall be dampproofed in accordance with Section R406.1.

R406.4.1 Panel Joints Sealed

Precast concrete foundation panel joints shall be sealed full height with a sealant meeting ASTM C 920, Type S or M, Grade NS, Class 25, Use NT, M or A. Joint sealant shall be installed in accordance with the manufacturer's installation instructions.

Related Code Sections


R406.4 Foundations, Precast Concrete Foundation System Dampproofing
Except where required by Section R406.2 to be waterproofed, precast concrete foundation walls enclosing habitable or useable spaces located below ...
Minnesota Residential Code 2015 > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.4 Precast Concrete Foundation System Dampproofing
R406.4 Foundations, Precast Concrete Foundation System Dampproofing
Except where required by Section R406.2 to be waterproofed, precast concrete foundation walls enclosing habitable or useable spaces located below ...
2020 Minnesota Residential Code > 4 Foundations > R406 Foundation Waterproofing and Dampproofing > R406.4 Precast Concrete Foundation System Dampproofing
1805.2 Soils and Foundations, Dampproofing
be dampproofed in accordance with this section. Wood foundation systems shall be constructed in accordance with AF&PA; PWF ...
Minnesota Building Code 2015 > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing
1805.2 Soils and Foundations, Dampproofing
be dampproofed in accordance with this section. Wood foundation systems shall be constructed in accordance with AWC PWF ...
2020 Minnesota Building Code > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing
Section 1805 Soils and Foundations, Dampproofing and Waterproofing
will not occur as determined by Section 1803.5.4, floors and walls for other than wood foundation systems shall be dampproofed in accordance with this section ...
2020 Minnesota Building Code > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE