// CODE SNIPPET
1910.1001(l)(2) Pre-Placement Examinations
JUMP TO FULL CODE CHAPTER
Before an employee is assigned to an occupation exposed to airborne concentrations of asbestos fibers at or above the TWA and/or excursion limit, a pre-placement medical examination shall be provided or made available by the employer.
Such examination shall include, as a minimum, a medical and work history; a complete physical examination of all systems with emphasis on the respiratory system, the cardiovascular system and digestive tract; completion of the respiratory disease standardized questionnaire in Appendix D to this section, Part 1; a chest roentgenogram (posterior-anterior 14 x 17 inches); pulmonary function tests to include forced vital capacity (FVC) and forced expiratory volume at 1 second (FEV(1.0)); and any additional tests deemed appropriate by the examining physician. Interpretation and classification of chest roentgenogram shall be conducted in accordance with Appendix E to this section.
Related Code Sections
1910.1001(l)(2) Toxic and Hazardous Substances, Pre-Placement Examinations
, a pre-placement medical examination shall be provided or made available by the employer ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(l) Medical Surveillance > 1910.1001(l)(2) Pre-Placement Examinations
1910.1020(c)(6)(i)(B) Toxic and Hazardous Substances,
The results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1020 Access to Employee Exposure and Medical Records > 1910.1020(c) Definitions > 1910.1020(c)(6) > 1910.1020(c)(6)(i) > 1910.1020(c)(6)(i)(B)
1910.1028(i)(5) Toxic and Hazardous Substances, Additional Examinations and Referrals
Where the results of the complete blood count required for the initial and periodic examinations indicate any of the following abnormal conditions ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(5) Additional Examinations and Referrals
1910.1003(g)(1) Toxic and Hazardous Substances, Examinations
Before an employee is assigned to enter a regulated area, a preassignment physical examination by a physician shall be provided. The examination ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1003 13 Carcinogens (4-Nitrobiphenyl, Etc.) > 1910.1003(g) Medical Surveillance > 1910.1003(g)(1) Examinations
1910.303(b)(1) Electrical, Examination
Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment ...
OSHA 1910 General Industry > S Electrical > 1910.303 General > 1910.303(b) Examination, Installation, and Use of Equipment > 1910.303(b)(1) Examination