// CODE SNIPPET
1910.178 Powered Industrial Trucks
JUMP TO FULL CODE CHAPTER
This section contains safety requirements relating to fire protection, design, maintenance, and use of fork trucks, tractors, platform lift trucks, motorized hand trucks, and other specialized industrial trucks powered by electric motors or internal combustion engines. This section does not apply to compressed air or nonflammable compressed gas-operated industrial trucks, nor to farm vehicles, nor to vehicles intended primarily for earth moving or over-the-road hauling.
All new powered industrial trucks acquired and used by an employer shall meet the design and construction requirements for powered industrial trucks established in the "American National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969", which is incorporated by reference as specified in §1910.6, except for vehicles intended primarily for earth moving or over-the-road hauling.
Approved trucks shall bear a label or some other identifying mark indicating approval by the testing laboratory. See paragraph (a)(7) of this section and paragraph 405 of "American National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969", which is incorporated by reference in paragraph (a)(2) of this section and which provides that if the powered industrial truck is accepted by a nationally recognized testing laboratory it should be so marked.
Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.
If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.
The user shall see that all nameplates and markings are in place and are maintained in a legible condition.
As used in this section, the term, approved truck or approved industrial truck means a truck that is listed or approved for fire safety purposes for the intended use by a nationally recognized testing laboratory, using nationally recognized testing standards. Refer to §1910.155(c)(3)(iv)(A) for definition of listed, and to §1910.7 for definition of nationally recognized testing laboratory.
For the purpose of this standard there are eleven different designations of industrial trucks or tractors as follows: D, DS, DY, E, ES, EE, EX, G, GS, LP, and LPS.
The D designated units are units similar to the G units except that they are diesel engine powered instead of gasoline engine powered.
The DS designated units are diesel powered units that are provided with additional safeguards to the exhaust, fuel and electrical systems. They may be used in some locations where a D unit may not be considered suitable.
The DY designated units are diesel powered units that have all the safeguards of the DS units and in addition do not have any electrical equipment including the ignition and are equipped with temperature limitation features.
The E designated units are electrically powered units that have minimum acceptable safeguards against inherent fire hazards.
The ES designated units are electrically powered units that, in addition to all of the requirements for the E units, are provided with additional safeguards to the electrical system to prevent emission of hazardous sparks and to limit surface temperatures. They may be used in some locations where the use of an E unit may not be considered suitable.
The EE designated units are electrically powered units that have, in addition to all of the requirements for the E and ES units, the electric motors and all other electrical equipment completely enclosed. In certain locations the EE unit may be used where the use of an E and ES unit may not be considered suitable.
The EX designated units are electrically powered units that differ from the E, ES, or EE units in that the electrical fittings and equipment are so designed, constructed and assembled that the units may be used in certain atmospheres containing flammable vapors or dusts.
The G designated units are gasoline powered units having minimum acceptable safeguards against inherent fire hazards.
The GS designated units are gasoline powered units that are provided with additional safeguards to the exhaust, fuel, and electrical systems. They may be used in some locations where the use of a G unit may not be considered suitable.
The LP designated unit is similar to the G unit except that liquefied petroleum gas is used for fuel instead of gasoline.
The LPS designated units are liquefied petroleum gas powered units that are provided with additional safeguards to the exhaust, fuel, and electrical systems. They may be used in some locations where the use of an LP unit may not be considered suitable.
The atmosphere or location shall have been classified as to whether it is hazardous or nonhazardous prior to the consideration of industrial trucks being used therein and the type of industrial truck required shall be as provided in paragraph (d) of this section for such location.
The industrial trucks specified under subparagraph (2) of this paragraph are the minimum types required but industrial trucks having greater safeguards may be used if desired.
For specific areas of use, see Table N-1 which tabulates the information contained in this section. References are to the corresponding classification as used in subpart S of this part.
Power-operated industrial trucks shall not be used in atmospheres containing hazardous concentration of acetylene, butadiene, ethylene oxide, hydrogen (or gases or vapors equivalent in hazard to hydrogen, such as manufactured gas), propylene oxide, acetaldehyde, cyclopropane, diethyl ether, ethylene, isoprene, or unsymmetrical dimethyl hydrazine (UDMH).
Only approved power-operated industrial trucks designated as EX may be used in atmospheres containing acetone, acrylonitrile, alcohol, ammonia, benzine, benzol, butane, ethylene dichloride, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas, propane, propylene, styrene, vinyl acetate, vinyl chloride, or xylenes in quantities sufficient to produce explosive or ignitable mixtures and where such concentrations of these gases or vapors exist continuously, intermittently or periodically under normal operating conditions or may exist frequently because of repair, maintenance operations, leakage, breakdown or faulty operation of equipment.
Power-operated industrial trucks designated as DY, EE, or EX may be used in locations where volatile flammable liquids or flammable gases are handled, processed or used, but in which the hazardous liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in the case of abnormal operation of equipment; also in locations in which hazardous concentrations of gases or vapors are normally prevented by positive mechanical ventilation but which might become hazardous through failure or abnormal operation of the ventilating equipment; or in locations which are adjacent to Class I, Division 1 locations, and to which hazardous concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive-pressure ventilation from a source of clear air, and effective safeguards against ventilation failure are provided.
**Trucks conforming to these types may also be used-see subdivision (c)(2)(x) and (c)(2)(xii) of this section.
Classes | Unclassified | Class I locations | Class II locations | Class III locations |
Description of classes | Locations not possessing atmospheres as described in other columns | Locations in which flammable gases or vapors are, or may be, present in the air in quantities sufficient to produce explosive or ignitible mixtures | Locations which are hazardous because of the presence of combustible dust | Locations where easily ignitible fibers or flyings are present but not likely to be in suspension in quantities sufficient to produce ignitible mixtures. |
Groups in classes | None | A | B | C | D | E | F | G | None |
Examples of locations or atmospheres in classes and groups | Piers and wharves inside and outside general storage, general industrial or commercial properties | Acetylene | Hydrogen | Ethyl ether | Gasoline Naphtha Alcohols Acetone Lacquer solvent Benzene |
Metal dust | Carbon black coal dust, coke dust | Grain dust, flour dust, starch dust, organic dust | Baled waste, cocoa fiber, cotton, excelsior, hemp, istle, jute, kapok, oakum, sisal, Spanish moss, synthetic fibers, tow. |
1 | 2 | 1 | 2 | 1 | 2 | ||
Divisions (nature of hazardous conditions) | None | Above condition exists continuously, intermittently, or periodically under normal operating conditions |
Above condition may occur accidentally as due to a puncture of a storage drum | Explosive mixture may be present under normal operating conditions, or where failure of equipment may cause the condition to exist simultaneously with arcing or sparking of electrical equipment, or where dusts of an electrically conducting nature may be present | Explosive mixture not normally present, but where deposits of dust may cause heat rise in electrical equipment, or where such deposits may be ignited by arcs or sparks from electrical equipment | Locations in which easily ignitible fibers or materials producing combustible flyings are handled, manufactured, or used | Locations in which easily ignitible fibers are stored or handled (except in the process of manufacture). |
Authorized uses of trucks by types in groups of classes and divisions | |||||||||||||||||
Groups in classes | None | A | B | C | D | A | B | C | D | E | F | G | E | F | G | None | None |
Type of truck authorized: | |||||||||||||||||
Diesel: |
|||||||||||||||||
Type D |
D** | ||||||||||||||||
Type DS |
DS | DS | DS | ||||||||||||||
Type DY |
DY | DY | DY | DY | |||||||||||||
Electric: |
|||||||||||||||||
Type E |
E** | E | |||||||||||||||
Type ES |
ES | ES | ES | ||||||||||||||
Type EE |
EE | EE | EE | EE | |||||||||||||
Type EX |
EX | EX | EX | EX | EX | EX | EX | ||||||||||
Gasoline: |
|||||||||||||||||
Type G |
G** | ||||||||||||||||
Type GS |
GS | GS | GS | ||||||||||||||
LP-Gas: |
|||||||||||||||||
Type LP |
LP** | ||||||||||||||||
Type LPS |
LPS | LPS | LPS | ||||||||||||||
Paragraph Ref. in No. 505 | 210.211 | 201 (a) |
203 (a) |
209 (a) |
204 (a), (b) |
202 (a) |
205 (a) |
209 (a) |
206 (a), (b) |
207(a) | 208 (a) |
**Trucks conforming to these types may also be used-see subdivision (c)(2)(x) and (c)(2)(xii) of this section.
Only approved power-operated industrial trucks designated as DS, DY, ES, EE, EX, GS, or LPS shall be used in locations where easily ignitable fibers are stored or handled, including outside storage, but are not being processed or manufactured. Industrial trucks designated as E, which have been previously used in these locations may be continued in use.
In locations used for the storage of hazardous liquids in sealed containers or liquefied or compressed gases in containers, approved power-operated industrial trucks designated as DS, ES, GS, or LPS may be used. This classification includes locations where volatile flammable liquids or flammable gases or vapors are used, but which, would become hazardous only in case of an accident or of some unusual operating condition. The quantity of hazardous material that might escape in case of accident, the adequacy of ventilating equipment, the total area involved, and the record of the industry or business with respect to explosions or fires are all factors that should receive consideration in determining whether or not the DS or DY, ES, EE, GS, LPS designated truck possesses sufficient safeguards for the location. Piping without valves, checks, meters and similar devices would not ordinarily be deemed to introduce a hazardous condition even though used for hazardous liquids or gases. Locations used for the storage of hazardous liquids or of liquified or compressed gases in sealed containers would not normally be considered hazardous unless subject to other hazardous conditions also.
Only approved power operated industrial trucks designated as EX shall be used in atmospheres in which combustible dust is or may be in suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced.
The EX classification usually includes the working areas of grain handling and storage plants, room containing grinders or pulverizers, cleaners, graders, scalpers, open conveyors or spouts, open bins or hoppers, mixers, or blenders, automatic or hopper scales, packing machinery, elevator heads and boots, stock distributors, dust and stock collectors (except all-metal collectors vented to the outside), and all similar dust producing machinery and equipment in grain processing plants, starch plants, sugar pulverizing plants, malting plants, hay grinding plants, and other occupancies of similar nature; coal pulverizing plants (except where the pulverizing equipment is essentially dust tight); all working areas where metal dusts and powders are produced, processed, handled, packed, or stored (except in tight containers); and other similar locations where combustible dust may, under normal operating conditions, be present in the air in quantities sufficient to produce explosive or ignitable mixtures.
Only approved power-operated industrial trucks designated as DY, EE, or EX shall be used in atmospheres in which combustible dust will not normally be in suspension in the air or will not be likely to be thrown into suspension by the normal operation of equipment or apparatus in quantities sufficient to produce explosive or ignitable mixtures but where deposits or accumulations of such dust may be ignited by arcs or sparks originating in the truck.
Only approved power-operated industrial trucks designated as DY, EE, or EX shall be used in locations which are hazardous because of the presence of easily ignitable fibers or flyings but in which such fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures.
On piers and wharves handling general cargo, any approved power-operated industrial truck designated as Type D, E, G, or LP may be used, or trucks which conform to the requirements for these types may be used.
Related Code Sections
1910.178 Materials Handling and Storage, Powered Industrial Trucks
, motorized hand trucks, and other specialized industrial trucks powered by electric motors or internal combustion engines. This section does not apply ...
1910.178(k) Materials Handling and Storage, Trucks and Railroad Cars
with powered industrial trucks. Wheel stops or other ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.178 Powered Industrial Trucks > 1910.178(k) Trucks and Railroad Cars
1910.178(a) Materials Handling and Storage, General Requirements
, motorized hand trucks, and other specialized industrial trucks powered by electric motors or internal combustion engines. This section does not apply ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.178 Powered Industrial Trucks > 1910.178(a) General Requirements
1910.178(l) Materials Handling and Storage, Operator Training
The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.178 Powered Industrial Trucks > 1910.178(l) Operator Training
1910.178(b) Materials Handling and Storage, Designations
For the purpose of this standard there are eleven different designations of industrial trucks or tractors as follows: D, DS, DY, E, ES, EE, EX, G, GS ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.178 Powered Industrial Trucks > 1910.178(b) Designations