1010.1.4.2 Power-Operated Doors
JUMP TO FULL CODE CHAPTER
Where means of egress doors are operated or assisted by power, the design shall be such that in the event of power failure, the door is capable of being opened manually to permit means of egress travel or closed where necessary to safeguard means of egress. The forces required to open these doors manually shall not exceed those specified in Section 1010.1.3, except that the force to set the door in motion shall not exceed 50 pounds (220 N). The door shall be capable of opening from any position to the full width of the opening in which such door is installed when a force is applied to the door on the side from which egress is made. Power-operated swinging doors, power-operated sliding doors and power-operated folding doors shall comply with BHMA A156.10. Power-assisted swinging doors and low-energy power-operated swinging doors shall comply with BHMA A156.19. Low-energy power-operated sliding doors and low-energy power-operated folding doors shall comply with BHMA A156.38.
Exceptions:
- Occupancies in Group I-3.
- Special purpose horizontal sliding, accordion or folding doors complying with Section 1010.1.4.3.
- For a biparting door in the emergency breakout mode, a door leaf located within a multiple-leaf opening shall be exempt from the minimum 32-inch (813 mm) single-leaf requirement of Section 1010.1.1, provided that a minimum 32-inch (813 mm) clear opening is provided when the two biparting leaves meeting in the center are broken out.
Related Code Sections
1010.1.4.2 Means of Egress, Power-Operated Doors
Where means of egress doors are operated or assisted by power, the design shall be such that in the event of power failure, the door is capable ...
Building Code 2018 of Illinois > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.4 Special Doors > 1010.1.4.2 Power-Operated Doors
1010.3.2 Means of Egress, Power-Operated Doors
Where means of egress doors are operated or assisted by power, the design shall be such that in the event of power failure, the door is capable ...
Building Code 2021 of Illinois > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.3 Special Doors > 1010.3.2 Power-Operated Doors
408.4.2 Special Detailed Requirements Based on Occupancy and Use, Power-Operated Doors and Locks
Power-operated sliding doors or power-operated locks for swinging doors shall be operable by a manual release mechanism at the door. Emergency ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 408 Group I-3 > 408.4 Locks > 408.4.2 Power-Operated Doors and Locks
408.4.2 Special Detailed Requirements Based on Occupancy and Use, Power-Operated Doors and Locks
Power-operated sliding doors or power-operated locks for swinging doors shall be operable by a manual release mechanism at the door. Emergency power ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 408 Group I-3 > 408.4 Locks > 408.4.2 Power-Operated Doors and Locks
1105.1.1 Accessibility, Automatic Doors
shall have one door be either a full power-operated door or a low-energy power-operated door . Where the public entrance includes ...
Building Code 2021 of Illinois > 11 Accessibility > 1105 Accessible Entrances > 1105.1 Public Entrances > 1105.1.1 Automatic Doors