• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.502(e) Positioning Device Systems

OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(e) Positioning Device Systems
JUMP TO FULL CODE CHAPTER
Positioning device systems and their use shall conform to the following provisions:

1926.502(e)(1)

Positioning devices shall be rigged such that an employee cannot free fall more than 2 feet (.6m).

1926.502(e)(2)

Positioning devices shall be secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever is greater.

1926.502(e)(3)

Connectors shall be drop forged, pressed or formed steel, or made of equivalent materials.

1926.502(e)(4)

Connectors shall have a corrosion-resistant finish, and all surfaces and edges shall be smooth to prevent damage to interfacing parts of this system.

1926.502(e)(5)

Connecting assemblies shall have a minimum tensile strength of 5,000 pounds (22.2 kN)

1926.502(e)(6)

Dee-rings and snaphooks shall be proof-tested to a minimum tensile load of 3,600 pounds (16 kN) without cracking, breaking, or taking permanent deformation.

1926.502(e)(7)

Snaphooks shall be sized to be compatible with the member to which they are connected to prevent unintentional disengagement of the snaphook by depression of the snaphook keeper by the connected member, or shall be a locking type snaphook designed and used to prevent disengagement of the snaphook by the contact of the snaphook keeper by the connected member. As of January 1, 1998, only locking type snaphooks shall be used.

1926.502(e)(8)

Unless the snaphook is a locking type and designed for the following connections, snaphooks shall not be engaged:

1926.502(e)(8)(i)

directly to webbing, rope or wire rope;

1926.502(e)(8)(iii)

to a dee-ring to which another snaphook or other connector is attached;

1926.502(e)(8)(iv)

to a horizontal lifeline; or

1926.502(e)(8)(v)

to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself.

1926.502(e)(8)(ii)

to each other;

1926.502(e)(9)

Positioning device systems shall be inspected prior to each use for wear, damage, and other deterioration, and defective components shall be removed from service.

1926.502(e)(10)

Body belts, harnesses, and components shall be used only for employee protection (as part of a personal fall arrest system or positioning device system) and not to hoist materials.

Related Code Sections


1926.502(e) Fall Protection, Positioning Device Systems
Positioning device systems and their use shall conform to the following provisions ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(e) Positioning Device Systems
1926.1423(g)(2) Cranes & Derricks in Construction, Anchorages for Personal Fall Arrest and Positioning Device Systems
meet the anchorage criteria in § 1926.502(d)(15) for personal fall arrest systems and § 1926.502(e)(2) for positioning device systems ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1423 Fall Protection > 1926.1423(g) Anchorage Criteria > 1926.1423(g)(2) Anchorages for Personal Fall Arrest and Positioning Device Systems
1926.502(e)(4) Fall Protection,
Connectors shall have a corrosion-resistant finish, and all surfaces and edges shall be smooth to prevent damage to interfacing parts of this system ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(e) Positioning Device Systems > 1926.502(e)(4)
1926.502(e)(5) Fall Protection,
Connecting assemblies shall have a minimum tensile strength of 5,000 pounds (22.2 kN ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(e) Positioning Device Systems > 1926.502(e)(5)
1926.502(e)(6) Fall Protection,
Dee-rings and snaphooks shall be proof-tested to a minimum tensile load of 3,600 pounds (16 kN) without cracking, breaking, or taking permanent ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(e) Positioning Device Systems > 1926.502(e)(6)
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE