2308.1.1 Portions Exceeding Limitations of Conventional Light-Frame Construction
JUMP TO FULL CODE CHAPTER
Where portions of a building of otherwise conventional light-frame construction exceed the limits of Section 2308.2, those portions and the supporting load path shall be designed in accordance with accepted engineering practice and the provisions of this code. For the purposes of this section, the term "portions" shall mean parts of buildings containing volume and area such as a room or a series of rooms. The extent of such design need only demonstrate compliance of the nonconventional light-framed elements with other applicable provisions of this code and shall be compatible with the performance of the conventional light-framed system.
Related Code Sections
2308.1.1 Wood, Portions Exceeding Limitations of Conventional Light-Frame Construction
Where portions of a building of otherwise conventional light-frame construction exceed the limits of Section 2308.2, those portions ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.1 General > 2308.1.1 Portions Exceeding Limitations of Conventional Light-Frame Construction
2308.1.1 Wood, Portions Exceeding Limitations of Conventional Light-Frame Construction
Where portions of a building of otherwise conventional light-frame construction exceed the limits of Section 2308.2, those portions ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.1 General > 2308.1.1 Portions Exceeding Limitations of Conventional Light-Frame Construction
2308.4.4 Wood, Framing Around Openings
of the conventional framing system. FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.4 Framing Around Openings
2308.8 Wood, Design of Elements
conventional construction contains structural elements exceeding the limits of Section 2308.2, these elements and the supporting load path shall ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.8 Design of Elements
2308.8 Wood, Design of Elements
conventional construction contains structural elements exceeding the limits of Section 2308.2, these elements and the supporting load path shall ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.8 Design of Elements