Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1113.1.2 Portion of a Building

Minnesota Accessibility Code 2015 > 11 Of the 2012 IBC With Minnesota Amendments > 1113 Change of Occupancy > 1113.1 General > 1113.1.2 Portion of a Building
JUMP TO FULL CODE CHAPTER
When a change of occupancy affects a portion of the building, all of the following accessible features shall be provided:
  1. At least one accessible building entrance.
  2. At least one accessible route from an accessible building entrance to the portion of the building undergoing the change of occupancy. In multistory buildings where the portion of the building undergoing the change of occupancy is located above or below the level of access and the number of occupants of the new occupancy exceeds 30 occupants, an accessible route shall be provided.
Exception: Regardless of occupant load, an accessible route shall be provided where the new occupancy is a public area of: a Group M occupancy; a medical care facility; a transportation facility; or a government or municipal facility.

3. Accessible parking, where parking is provided.

4. At least one accessible route from accessible parking to an accessible building entrance.

5. At least one accessible family or assisted-use toilet room or bathing room, or one accessible male and one accessible female toilet or bathing room, located on an accessible route not more than one story above or one story below the portion of the building undergoing the change in occupancy. Signage complying with Section 1112.8.3.3 shall be provided.

Where it is technically infeasible to comply with the new construction criteria for a change of occupancy, items 1 to 5 shall conform to the criteria to the maximum extent technically feasible.

Related Code Sections


1113.1.2 Of the 2012 IBC With Minnesota Amendments, Portion of a Building
When a change of occupancy affects a portion of the building, all of the following accessible features shall be provided: At least one ...
Minnesota Accessibility Code 2015 > 11 Of the 2012 IBC With Minnesota Amendments > 1113 Change of Occupancy > 1113.1 General > 1113.1.2 Portion of a Building
402.5 Prescriptive Compliance Method, Smoke Alarms in Existing Portions of a Building
Where an addition is made to a building or structure of a Group R or I-1 occupancy, the existing building shall be provided with smoke alarms ...
Minnesota Conservation Code for Existing Buildings 2015 > 4 Prescriptive Compliance Method > 402 Additions > 402.5 Smoke Alarms in Existing Portions of a Building
1104.1 Additions, Smoke Alarms in Existing Portions of a Building
Where an addition is made to a building or structure of a Group R or I-1 occupancy, the existing building shall be provided with smoke alarms ...
2020 Minnesota Conservation Code for Existing Buildings > 11 Additions > 1104 Smoke Alarms in Occupancy Groups R and I-1 > 1104.1 Smoke Alarms in Existing Portions of a Building
1104.1 Additions, Smoke Alarms in Existing Portions of a Building
Where an addition is made to a building or structure of a Group R or I-1 occupancy, the existing building shall be provided with smoke alarms ...
Minnesota Conservation Code for Existing Buildings 2015 > 11 Additions > 1104 Smoke Alarms in Occupancy Groups R and I-1 > 1104.1 Smoke Alarms in Existing Portions of a Building
502.7 Prescriptive Compliance Method, Carbon Monoxide Alarms in Existing Portions of a Building
Where an addition is made to a building or structure of Group I-1, I-2, I-4 or R occupancy, the existing building shall be provided with carbon ...
2020 Minnesota Conservation Code for Existing Buildings > 5 Prescriptive Compliance Method > 502 Additions > 502.7 Carbon Monoxide Alarms in Existing Portions of a Building
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING