2206.2.5 Portable Tanks
JUMP TO FULL CODE CHAPTER
Where approved by the fire code official, portable tanks are allowed to be temporarily used in conjunction with the dispensing of Class I, II or IIIA liquids into the fuel tanks of motor vehicles or motorized equipment on premises not normally accessible to the public. The approval shall include a definite time limit.
Related Code Sections
2206.2.5 Motor Fuel-Dispensing Facilities and Repair Garages, Portable Tanks
Where approved by the fire code official , portable tanks are allowed to be temporarily used in conjunction with the dispensing of Class I, II ...
2012 North Carolina Fire Code > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2206 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2206.2 Method of Storage > 2206.2.5 Portable Tanks
2306.2.5 Motor Fuel-Dispensing Facilities and Repair Garages, Portable Tanks
Where approved by the fire code official, portable tanks are allowed to be temporarily used in conjunction with the dispensing of Class I, II or III ...
2018 North Carolina Fire Prevention Code > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2306 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2306.2 Method of Storage > 2306.2.5 Portable Tanks
3704.2.2.7.5 Highly Toxic and Toxic Materials, Portable Tanks and Cylinders
The maximum flow rate of release for portable tanks and cylinders shall be calculated based on the total release from the cylinder or tank within ...
2012 North Carolina Fire Code > 37 Highly Toxic and Toxic Materials > 3704 Highly Toxic and Toxic Compressed Gases > 3704.2 Indoor Storage and Use > 3704.2.2 General Indoor Requirements > 3704.2.2.7 Treatment Systems > 3704.2.2.7.5 Portable Tanks and Cylinders
6004.2.2.7.5 Highly Toxic and Toxic Materials, Portable Tanks and Cylinders
The maximum flow rate of release for portable tanks and cylinders shall be calculated based on the total release from the cylinder or tank within ...
2018 North Carolina Fire Prevention Code > 60 Highly Toxic and Toxic Materials > 6004 Highly Toxic and Toxic Compressed Gases > 6004.2 Indoor Storage and Use > 6004.2.2 General Indoor Requirements > 6004.2.2.7 Treatment Systems > 6004.2.2.7.5 Portable Tanks and Cylinders
3404.3 Flammable and Combustible Liquids, Container and Portable Tank Storage
Storage of flammable and combustible liquids in closed containers that do not exceed 60 gallons (227 L) in individual capacity and portable tanks ...
2012 North Carolina Fire Code > 34 Flammable and Combustible Liquids > 3404 Storage > 3404.3 Container and Portable Tank Storage