1028.8.2.3 Portable Escape Ladder
Go To Full Code Chapter
An emergency escape and rescue opening conforming to the requirements of Section 1026 within each bedroom for transient use, such opening to have both a sill not more than 14 feet (4267 mm) above level grade directly below and, as permanent equipment, a portable escape ladder that attaches securely to such sill. Such ladder shall be constructed with rigid rungs designed to stand off from the building wall, shall be capable of sustaining a minimum weight of 1,000 pounds (454 kg), shall extend to grade, and shall provide unobstructed egress to legal open space.
Related Code Sections
1028.8.2.3 Means of Egress, Portable Escape Ladder
both a sill not more than 14 feet (4267 mm) above level grade directly below and, as permanent equipment, a portable escape ladder that attaches securely ...
AJ704.4 Existing Buildings and Structures, Means of Egress
equipment, a
portable escape ladder that attaches securely to such sill. Such ladder shall be
constructed with rigid rungs designed to stand off from ...
AJ702.4 Existing Buildings and Structures, Means of Egress
and, as permanent equipment, a portable escape ladder that attaches securely to such sill. Such ladder shall be constructed with rigid rungs designed ...
Section AJ702 Existing Buildings and Structures, Bed and Breakfast Dwellings
grade directly below and, as permanent equipment, a portable escape ladder that attaches securely to such sill. Such ladder shall be constructed ...
Section AJ704 Existing Buildings and Structures, Bed and Breakfast Dwellings
, a
portable escape ladder that attaches securely to such sill. Such ladder shall be
constructed with rigid rungs designed to stand off from the building ...