605.19 Polyethylene Plastic
JUMP TO FULL CODE CHAPTER
Mechanical joints shall be installed in accordance with the manufacturer's instructions.
Polyethylene pipe shall be cut square, with a cutter designed for plastic pipe. Except where joined by heat fusion, pipe ends shall be chamfered to remove sharp edges. Kinked pipe shall not be installed. The minimum pipe bending radius shall not be less than 30 pipe diameters, or the minimum coil radius, whichever is greater. Piping shall not be bent beyond straightening of the curvature of the coil. Bends shall not be permitted within 10 pipe diameters of any fitting or valve. Stiffener inserts installed with compression-type couplings and fittings shall not extend beyond the clamp or nut of the coupling or fitting.
Related Code Sections
605.19 Water Supply and Distribution, Polyethylene Plastic
Joints between polyethylene plastic pipe and tubing or fittings shall comply with Sections 605.19.1 through 605.19.4 ...
2014 FBC - Plumbing, 5th edition > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.19 Polyethylene Plastic
705.12 Sanitary Drainage, Polyethylene Plastic Pipe
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section 705.12.1 or 705.12.2 ...
2020 FBC - Plumbing, 7th edition > 7 Sanitary Drainage > 705 Joints > 705.12 Polyethylene Plastic Pipe
705.13 Sanitary Drainage, Polyethylene Plastic Pipe
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section 705.13.1 or 705.13.2 ...
2017 FBC - Plumbing, 6th edition > 7 Sanitary Drainage > 705 Joints > 705.13 Polyethylene Plastic Pipe
705.16 Sanitary Drainage, Polyethylene Plastic Pipe
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section 705.16.1 or 705.16.2 ...
2014 FBC - Plumbing, 5th edition > 7 Sanitary Drainage > 705 Joints > 705.16 Polyethylene Plastic Pipe
P3003.12 Sanitary Drainage, Polyethylene Plastic Pipe
Joints between polyethylene plastic pipe and fittings shall be underground and shall comply with Section P3003.12.1 or P3003.12.2 ...
2017 FBC - Residential, 6th edition > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.12 Polyethylene Plastic Pipe