605.25 Polyethylene of Raised Temperature Plastic
JUMP TO FULL CODE CHAPTER
Flared pipe ends shall be made by a tool designed for that operation.
Mechanical joints shall be installed in accordance with the manufacturer's instructions. Fittings for polyethylene of raised temperature plastic tubing shall comply with the applicable standards listed in Table 605.5 and shall be installed in accordance with the manufacturer's instructions. Polyethylene of raised temperature plastic tubing shall be factory marked with the applicable standards for the fittings that the manufacturer of the tubing specifies for use with the tubing.
Related Code Sections
605.25 Water Supply and Distribution, Polyethylene of Raised Temperature Plastic
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Sections 605.25.1 and 605.25.2 ...
2014 FBC - Plumbing, 5th edition > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.25 Polyethylene of Raised Temperature Plastic
P2905.19 Water Supply and Distribution, Polyethylene of Raised Temperature Plastic
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Section P2905.19.1 and Section P2905.19.2 ...
2014 FBC - Residential, 5th edition > 29 Water Supply and Distribution > P2905 Materials, Joints and Connections > P2905.19 Polyethylene of Raised Temperature Plastic
P2906.19 Water Supply and Distribution, Polyethylene of Raised Temperature Plastic
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Section P2906.19.1 ...
2017 FBC - Residential, 6th edition > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.19 Polyethylene of Raised Temperature Plastic
P2906.20 Water Supply and Distribution, Polyethylene of Raised Temperature Plastic
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Sections P2906.20.1, P2906.20.2 ...
2020 FBC - Residential, 7th edition > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.20 Polyethylene of Raised Temperature Plastic
605.25.1 Water Supply and Distribution, Flared Joints
Flared pipe ends shall be made by a tool designed for that operation ...
2014 FBC - Plumbing, 5th edition > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.25 Polyethylene of Raised Temperature Plastic > 605.25.1 Flared Joints