• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3604.3 Point of Attachment

2017 FBC - Residential, 6th edition > 36 Services > E3604 Overhead Service and Service- Entrance Conductor Installation > E3604.3 Point of Attachment
JUMP TO FULL CODE CHAPTER
The point of attachment of the overhead service conductors to a building or other structure shall provide the minimum clearances as specified in Sections E3604.1 through E3604.2.2. The point of attachment shall be not less than 10 feet (3048 mm) above finished grade. (230.26)

Related Code Sections


E3604.3 Services, Point of Attachment
The point of attachment of the overhead service conductors to a building or other structure shall provide the minimum clearances as specified ...
2017 FBC - Residential, 6th edition > 36 Services > E3604 Overhead Service and Service- Entrance Conductor Installation > E3604.3 Point of Attachment
E3604.3 Services, Point of Attachment
The point of attachment of the service-drop conductors to a building or other structure shall provide the minimum clearances as specified in Sections ...
2014 FBC - Residential, 5th edition > 36 Services > E3604 Overhead Service and Service-Entrance Conductor Installation > E3604.3 Point of Attachment
E3605.9.3 Services, Service-Head Location
Service heads, and goosenecks in service-entrance cables, shall be located above the point of attachment of the service-drop or overhead service ...
2014 FBC - Residential, 5th edition > 36 Services > E3605 Service-Entrance Conductors > E3605.9 Overhead Service Locations > E3605.9.3 Service-Head Location
E3605.9.3 Services, Service-Head Location
Service heads, and goosenecks in service-entrance cables, shall be located above the point of attachment of the service-drop or overhead service ...
2017 FBC - Residential, 6th edition > 36 Services > E3605 Service-Entrance Conductors > E3605.9 Overhead Service Locations > E3605.9.3 Service-Head Location
E3609.6 Services, Metal Water Piping Bonding
The points of attachment of the bonding jumper(s) shall be accessible ...
2014 FBC - Residential, 5th edition > 36 Services > E3609 Bonding > E3609.6 Metal Water Piping Bonding
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE