1926.302(b) Pneumatic Power Tools
Go To Full Code Chapter
1926.302(b)(1)
Pneumatic power tools shall be secured to the hose or whip by some positive means to prevent the tool from becoming accidentally disconnected.
1926.302(b)(2)
Safety clips or retainers shall be securely installed and maintained on pneumatic impact (percussion) tools to prevent attachments from being accidentally expelled.
1926.302(b)(3)
All pneumatically driven nailers, staplers, and other similar equipment provided with automatic fastener feed, which operate at more than 100 p.s.i. pressure at the tool shall have a safety device on the muzzle to prevent the tool from ejecting fasteners, unless the muzzle is in contact with the work surface.
1926.302(b)(4)
Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment which meets the requirements of Subpart E of this part. The 30 p.s.i. requirement does not apply for concrete form, mill scale and similar cleaning purposes.
1926.302(b)(5)
The manufacturer's safe operating pressure for hoses, pipes, valves, filters, and other fittings shall not be exceeded,
1926.302(b)(6)
The use of hoses for hoisting or lowering tools shall not be permitted.
1926.302(b)(7)
All hoses exceeding 1/2-inch inside diameter shall have a safety device at the source of supply or branch line to reduce pressure in case of hose failure.
1926.302(b)(8)
Airless spray guns of the type which atomize paints and fluids at high pressures (1,000 pounds or more per square inch) shall be equipped with automatic or visible manual safety devices which will prevent pulling of the trigger to prevent release of the paint or fluid until the safety device is manually released.
1926.302(b)(9)
In lieu of the above, a diffuser nut which will prevent high pressure, high velocity release, while the nozzle tip is removed, plus a nozzle tip guard which will prevent the tip from coming into contact with the operator, or other equivalent protection, shall be provided.
1926.302(b)(10) "Abrasive Blast Cleaning Nozzles"
The blast cleaning nozzles shall be equipped with an operating valve which must be held open manually. A support shall be provided on which the nozzle may be mounted when it is not in use.
Upcodes Diagrams
Related Code Sections
1926.302(b) Tools - Hand and Power, Pneumatic Power Tools
Pneumatic power tools shall be secured to the hose or whip by some positive means to prevent the tool from becoming accidentally disconnected ...
1926.302(b)(5) Tools - Hand and Power,
The manufacturer's safe operating pressure for hoses, pipes, valves, filters, and other fittings shall not be exceeded ...
1926.302(b)(6) Tools - Hand and Power,
The use of hoses for hoisting or lowering tools shall not be permitted ...
1926.302(b)(7) Tools - Hand and Power,
All hoses exceeding 1/2-inch inside diameter shall have a safety device at the source of supply or branch line to reduce pressure in case of hose ...
1926.302(b)(8) Tools - Hand and Power,
Airless spray guns of the type which atomize paints and fluids at high pressures (1,000 pounds or more per square inch) shall be equipped ...