• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

705.3.2 Pneumatic Leak Tests

Fuel Gas Code 2018 of Colorado > 7 Gaseous Hydrogen Systems > 705 (IFGC) Testing of Hydrogen Piping Systems > 705.3 Pressure Tests > 705.3.2 Pneumatic Leak Tests
JUMP TO FULL CODE CHAPTER
The pneumatic test pressure shall be not less than one-and-one-half times the maximum working pressure for systems less than 125 psig (862 kPa gauge) and not less than 5 psig (34.5 kPa gauge), whichever is greater. For working pressures at or above 125 psig (862 kPa gauge), the pneumatic test pressure shall be not less than 110 percent of the maximum working pressure.

Related Code Sections


5703.6.3.1 Flammable and Combustible Liquids, Existing Piping
Existing piping shall be tested in accordance with this section where the fire code official has reasonable cause to believe that a leak exists ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5703 General Requirements > 5703.6 Piping Systems > 5703.6.3 Testing > 5703.6.3.1 Existing Piping
5505.1.2.6 Cryogenic Fluids, Testing
Piping systems shall be tested and proven free of leaks after installation as required by the standards to which they were designed and constructed ...
Fire Code 2018 of Colorado > 55 Cryogenic Fluids > 5505 Use and Handling > 5505.1 General > 5505.1.2 Piping Systems > 5505.1.2.6 Testing
602.2.1.3 Duct Systems, Pneumatic Tubing
Combustible pneumatic tubing exposed within a plenum shall be listed and labeled as having a peak optical density not greater than 0.50, an average ...
Mechanical Code 2018 of Colorado > 6 Duct Systems > 602 Plenums > 602.2 Construction > 602.2.1 Materials Within Plenums > 602.2.1.3 Pneumatic Tubing
602.2.1.3 Duct Systems, Pneumatic Tubing
not greater than 0.15, and a flame spread of not greater than 5 feet (1524 mm) when tested in accordance with UL 1820. Combustible pneumatic tubing shall ...
Mechanical Code 2015 of Colorado > 6 Duct Systems > 602 Plenums > 602.2 Construction > 602.2.1 Materials Within Plenums > 602.2.1.3 Pneumatic Tubing
2305.2.5 Motor Fuel-Dispensing Facilities and Repair Garages, Leak Detectors
Leak detection devices required by Section 2306.7.7.1 shall be checked and tested not less than annually in accordance with the manufacturer's ...
Fire Code 2018 of Colorado > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2305 Operational Requirements > 2305.2 Equipment Maintenance and Inspection > 2305.2.5 Leak Detectors
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE